BACKGROUND

Embolism due to accidental intra-arterial injection of a soft tissue filler (STF) can lead to serious complications. Physicians practice aspiration as a safety test before injection to rule out intra-arterial placement of the needle tip. The value of aspiration as a safety test is evaluated in this study, which also considered the rheological properties of different STFs and their needle dimensions.

METHODS

Aspiration with eleven different needle sizes and 24 different STFs was performed using Ringer's lactate (RL) colored with blue skin marking ink and secondly an empty saline bag containing anticoagulated blood, both pressurized to 150 mm Hg to mimic arterial blood pressure. Time between the start of aspiration and liquid in the needle hub was recorded.

RESULTS

A total of 340 individual aspiration tests with different STFs and needles were performed, of which 112 yielded true-positive results within 1-s and 128 yielded false-negative results after 10 s. Positive results between one and ten seconds were seen in 101 aspiration tests.

CONCLUSIONS

True-positive results were seen in 33% of the tests performed with STFs within 1 s of aspiration. Aspiration test results are influenced by needle diameter, needle length, and rheological properties of STFs. Additional safety measures are necessary to further reduce risk of inadvertent intravascular injection of STFs.

摘要

背景

意外动脉内注射软组织填充剂(STF)导致的栓塞可引发严重并发症。医生在注射前进行回抽作为安全测试,以排除针尖位于动脉内的情况。本研究评估了回抽作为安全测试的价值,同时还考虑了不同软组织填充剂的流变学特性及其针的尺寸。

方法

使用蓝色皮肤标记墨水染色的乳酸林格液(RL),其次使用装有抗凝血液的空盐水袋,将两者均加压至150 mmHg以模拟动脉血压,对11种不同尺寸的针和24种不同的软组织填充剂进行回抽操作。记录回抽开始至针座内出现液体的时间。

结果

共进行了340次针对不同软组织填充剂和针的回抽测试,其中112次在1秒内产生真阳性结果,128次在10秒后产生假阴性结果。101次回抽测试在1至10秒之间出现阳性结果。

结论

在对软组织填充剂进行的回抽测试中,33%的测试在1秒内出现真阳性结果。回抽测试结果受针直径、针长度和软组织填充剂流变学特性的影响。需要采取额外的安全措施以进一步降低软组织填充剂意外血管内注射的风险。