Suppr超能文献

脑室导管经皮出口处脑脊液漏是成人神经外科患者脑室引流相关感染的关键危险因素。

Cerebrospinal Fluid Leak at Percutaneous Exit of Ventricular Catheter as a Crucial Risk Factor for External Ventricular Drainage-Related Infection in Adult Neurosurgical Patients.

作者信息

Park Jaechan, Choi Yeon-Ju, Ohk Boram, Chang Hyun-Ha

机构信息

Department of Neurosurgery, Department of Internal Medicine, Kyungpook National University, Daegu, Republic of Korea; Research Center for Neurosurgical Robotic Systems, Department of Internal Medicine, Kyungpook National University, Daegu, Republic of Korea.

Department of Neurosurgery, Department of Internal Medicine, Kyungpook National University, Daegu, Republic of Korea; Research Center for Neurosurgical Robotic Systems, Department of Internal Medicine, Kyungpook National University, Daegu, Republic of Korea.

出版信息

World Neurosurg. 2018 Jan;109:e398-e403. doi: 10.1016/j.wneu.2017.09.190. Epub 2017 Oct 5.

Abstract

OBJECTIVE

The placement of a ventricular catheter for temporary cerebrospinal fluid (CSF) diversion is associated with a considerable risk of CSF infection. The authors investigated the effect of a CSF leak on CSF-related infection and the predisposing factors for a CSF leak.

METHODS

Fifty-two patients who underwent external ventricular drainage (EVD) for acute hydrocephalus associated with a subarachnoid hemorrhage or intraventricular hemorrhage (IVH) were enrolled in this prospective study. A CSF leak-detection paper (small sterilized filter paper) was applied at the percutaneous catheter exit site to check for any bloody CSF leak. In addition, radiologic and clinical data were collected.

RESULTS

Four of the 52 patients (7.7%) developed an EVD-related CSF infection from organisms including Staphylococcus epidermidis (n = 3) and Staphylococcus hominis (n = 1). A prolonged CSF leak >1 day was detected in 9 patients (17.3%) and revealed as a significant risk factor for CSF infection with a 44.4% positive predictive value. Moreover, an IVH >10 mL was found in 11 patients (21.2%) and revealed as a significant predisposing factor for a CSF leak at the percutaneous catheter exit.

CONCLUSIONS

A prolonged CSF leak for >1 day at the percutaneous catheter exit site is a crucial risk factor for EVD-related CSF infection and an IVH >10 mL is a predisposing factor for a CSF leak.

摘要

目的

放置脑室导管进行临时脑脊液(CSF)分流与脑脊液感染的风险相当高有关。作者研究了脑脊液漏对脑脊液相关感染的影响以及脑脊液漏的易感因素。

方法

52例因蛛网膜下腔出血或脑室内出血(IVH)相关的急性脑积水而接受脑室外引流(EVD)的患者纳入了这项前瞻性研究。在经皮导管出口部位应用脑脊液漏检测纸(小型无菌滤纸)以检查是否有血性脑脊液漏。此外,收集了影像学和临床数据。

结果

52例患者中有4例(7.7%)发生了与EVD相关的脑脊液感染,感染源包括表皮葡萄球菌(n = 3)和人葡萄球菌(n = 1)。9例患者(17.3%)检测到脑脊液漏持续时间>1天,这被证明是脑脊液感染的一个重要危险因素,阳性预测值为44.4%。此外,11例患者(21.2%)发现脑室内出血>10 mL,这被证明是经皮导管出口处脑脊液漏的一个重要易感因素。

结论

经皮导管出口部位脑脊液漏持续时间>1天是与EVD相关的脑脊液感染的关键危险因素,而脑室内出血>10 mL是脑脊液漏的易感因素。