Suppr超能文献

使用多种曝光参数进行CBCT扫描时,对根管充填材料产生的图像伪影进行定量评估。

Quantitative assessment of image artifacts from root filling materials on CBCT scans made using several exposure parameters.

作者信息

Rabelo Katharina Alves, Cavalcanti Yuri Wanderley, de Oliveira Pinto Martina Gerlane, Sousa Melo Saulo Leonardo, Campos Paulo Sérgio Flores, de Andrade Freitas Oliveira Luciana Soares, de Melo Daniela Pita

机构信息

Department of Oral Diagnosis, State University of Paraíba, Campina Grande, Brazil.

Department of Oral Pathology, Radiology and Medicine, University of Iowa, Iowa City, USA.

出版信息

Imaging Sci Dent. 2017 Sep;47(3):189-197. doi: 10.5624/isd.2017.47.3.189. Epub 2017 Sep 21.

Abstract

PURPOSE

To quantify artifacts from different root filling materials in cone-beam computed tomography (CBCT) images acquired using different exposure parameters.

MATERIALS AND METHODS

Fifteen single-rooted teeth were scanned using 8 different exposure protocols with 3 different filling materials and once without filling material as a control group. Artifact quantification was performed by a trained observer who made measurements in the central axial slice of all acquired images in a fixed region of interest using ImageJ. Hyperdense artifacts, hypodense artifacts, and the remaining tooth area were identified, and the percentages of hyperdense and hypodense artifacts, remaining tooth area, and tooth area affected by the artifacts were calculated. Artifacts were analyzed qualitatively by 2 observers using the following scores: absence (0), moderate presence (1), and high presence (2) for hypodense halos, hypodense lines, and hyperdense lines. Two-way ANOVA and the post-hoc Tukey test were used for quantitative and qualitative artifact analysis. The Dunnet test was also used for qualitative analysis. The significance level was set at <.05.

RESULTS

There were no significant interactions among the exposure parameters in the quantitative or qualitative analysis. Significant differences were observed among the studied filling materials in all quantitative analyses. In the qualitative analyses, all materials differed from the control group in terms of hypodense and hyperdense lines (<.05). Fiberglass posts did not differ statistically from the control group in terms of hypodense halos (>.05).

CONCLUSION

Different exposure parameters did not affect the objective or subjective observations of artifacts in CBCT images; however, the filling materials used in endodontic restorations did affect both types of assessments.

摘要

目的

在使用不同曝光参数获取的锥束计算机断层扫描(CBCT)图像中,对不同根管充填材料产生的伪影进行量化。

材料与方法

使用8种不同的曝光方案对15颗单根牙进行扫描,其中3种不同的充填材料各扫描一次,未充填材料的作为对照组扫描一次。由一名经过培训的观察者进行伪影量化,该观察者使用ImageJ在所有采集图像的中央轴位切片的固定感兴趣区域进行测量。识别高密度伪影、低密度伪影和剩余牙体区域,并计算高密度和低密度伪影的百分比、剩余牙体区域以及受伪影影响的牙体区域。由2名观察者使用以下评分对伪影进行定性分析:低密度晕、低密度线和高密度线的不存在(0分)、中度存在(1分)和高度存在(2分)。采用双向方差分析和事后Tukey检验进行定量和定性伪影分析。还使用Dunnet检验进行定性分析。显著性水平设定为<.05。

结果

在定量或定性分析中,曝光参数之间没有显著的交互作用。在所有定量分析中,观察到所研究的充填材料之间存在显著差异。在定性分析中,所有材料在低密度和高密度线方面与对照组不同(<.05)。玻璃纤维桩在低密度晕方面与对照组无统计学差异(>.05)。

结论

不同的曝光参数不影响CBCT图像中伪影的客观或主观观察;然而,牙髓修复中使用的充填材料确实影响这两种评估。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/f82c/5620464/2d2366225c73/isd-47-189-g001.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验