Suppr超能文献

牙种植体的线束硬化伪影:锥形束CT与64层螺旋CT扫描仪的比较

Beam hardening artifacts by dental implants: Comparison of cone-beam and 64-slice computed tomography scanners.

作者信息

Esmaeili Farzad, Johari Masume, Haddadi Pezhman

机构信息

Department of Oral Radiology, Tabriz University of Medical Sciences, Tabriz, Iran.

出版信息

Dent Res J (Isfahan). 2013 May;10(3):376-81.

Abstract

BACKGROUND

Cone beam computed tomography (CBCT) is an alternative to a computed tomography (CT) scan, which is appropriate for a wide range of craniomaxillofacial indications. The long-term use of metallic materials in dentistry means that artifacts caused by metallic restorations in the oral cavity should be taken into account when utilizing CBCT and CT scanners. The aim of this study was to quantitatively compare the beam hardening artifacts produced by dental implants between CBCT and a 64-Slice CT scanner.

MATERIALS AND METHODS

In this descriptive study, an implant drilling model similar to the human mandible was used in the present study. The implants (Dentis) were placed in the canine, premolar and molar areas. Three series of scans were provided from the implant areas using Somatom Sensation 64-slice and NewTom VGi (CBCT) CT scanners. Identical images were evaluated by three radiologists. The artifacts in each image were determined based on pre-determined criteria. Kruskal-Wallis test was used to compare mean values; Mann-Whitney U test was used for two-by-two comparisons when there was a statistical significance (P < 0.05).

RESULTS

The images of the two scanners had similar resolutions in axial sections (P = 0.299). In coronal sections, there were significant differences in the resolutions of the images produced by the two scanners (P < 0.001), with a higher resolution in the images produced by NewTom VGi scanner. On the whole, there were significant differences between the resolutions of the images produced by the two CT scanners (P < 0.001), with higher resolution in the images produced by NewTom VGi scanner in comparison to those of Somatom Sensation.

CONCLUSION

Given the high quality of the images produced by NewTom VGi and the lower costs in comparison to CT, the use of the images of this scanner in dental procedures is recommended, especially in patients with extensive restorations, multiple prostheses and previous implants.

摘要

背景

锥形束计算机断层扫描(CBCT)是计算机断层扫描(CT)的一种替代方法,适用于广泛的颅颌面适应症。牙科中金属材料的长期使用意味着在使用CBCT和CT扫描仪时应考虑口腔中金属修复体引起的伪影。本研究的目的是定量比较CBCT和64层CT扫描仪之间牙种植体产生的束硬化伪影。

材料与方法

在本描述性研究中,使用了类似于人类下颌骨的种植体钻孔模型。将种植体(Dentis)放置在犬齿、前磨牙和磨牙区域。使用Somatom Sensation 64层CT扫描仪和NewTom VGi(CBCT)CT扫描仪从种植体区域进行了三组扫描。三位放射科医生对相同的图像进行了评估。根据预先确定的标准确定每张图像中的伪影。使用Kruskal-Wallis检验比较平均值;当有统计学意义(P<0.05)时,使用Mann-Whitney U检验进行两两比较。

结果

两台扫描仪的图像在轴位上具有相似的分辨率(P=0.299)。在冠状位上,两台扫描仪产生的图像分辨率存在显著差异(P<0.001),NewTom VGi扫描仪产生的图像分辨率更高。总体而言,两台CT扫描仪产生的图像分辨率存在显著差异(P<0.001),与Somatom Sensation相比,NewTom VGi扫描仪产生的图像分辨率更高。

结论

鉴于NewTom VGi产生的图像质量高且成本低于CT,建议在牙科手术中使用该扫描仪的图像,特别是在有广泛修复、多个假体和既往有种植体的患者中。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/871c/3760363/406ac696afd2/DRJ-10-376-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验