Bansal R P, Joshi R C, Chandra U, Sharma B
Indian Veterinary Research Institute, Nainital.
Acta Virol. 1988 May;32(3):275-7.
A slightly modified latex agglutination test was applied for detection of rinderpest antigen. The antigen was added to sensitized latex particles in the presence of hyperimmune antiserum to facilitate agglutination. Out of 129 samples tested by latex agglutination (LA), solid phase aggregation of coated erythrocytes (SPACE), reverse phase passive haemagglutination (RPHA) and counter immunoelectrophoresis (CIE) test, 86.0, 86.8, 84.4 and 79.8 per cent, respectively, were found positive.
采用一种稍作改良的乳胶凝集试验检测牛瘟抗原。在超免疫抗血清存在的情况下,将抗原添加到致敏乳胶颗粒中以促进凝集。在通过乳胶凝集(LA)、包被红细胞固相凝集(SPACE)、反向被动血凝(RPHA)和对流免疫电泳(CIE)试验检测的129个样本中,分别有86.0%、86.8%、84.4%和79.8%呈阳性。