Al Sidairi Hilal, Binkhamis Khalifa, Jackson Colleen, Roberts Catherine, Heinstein Charles, MacDonald Jimmy, Needle Robert, Hatchette Todd F, LeBlanc Jason J
Division of Microbiology, Department of Pathology and Laboratory Medicine, Nova Scotia Health Authority (NSHA), Halifax, NS, Canada.
Dalhousie University, Halifax, NS, Canada.
J Med Microbiol. 2017 Nov;66(11):1628-1634. doi: 10.1099/jmm.0.000616. Epub 2017 Oct 16.
Serology remains the mainstay for diagnosis of Epstein-Barr virus (EBV) infection. This study compared two automated platforms (BioPlex 2200 and Architect i2000SR) to test three EBV serological markers: viral capsid antigen (VCA) immunoglobulins of class M (IgM), VCA immunoglobulins of class G (IgG) and EBV nuclear antigen-1 (EBNA-1) IgG. Using sera from 65 patients at various stages of EBV disease, BioPlex demonstrated near-perfect agreement for all EBV markers compared to a consensus reference. The agreement for Architect was near-perfect for VCA IgG and EBNA-1 IgG, and substantial for VCA IgM despite five equivocal results. Since the majority of testing in our hospital was from adults with EBNA-1 IgG positive results, post-implementation analysis of an EBNA-based algorithm showed advantages over parallel testing of the three serologic markers. This small verification demonstrated that both automated systems for EBV serology had good performance for all EBV markers, and an EBNA-based testing algorithm is ideal for an adult hospital.
血清学仍然是诊断爱泼斯坦-巴尔病毒(EBV)感染的主要方法。本研究比较了两种自动化检测平台(BioPlex 2200和Architect i2000SR)对三种EBV血清学标志物的检测:病毒衣壳抗原(VCA)M类免疫球蛋白(IgM)、VCA G类免疫球蛋白(IgG)和EBV核抗原-1(EBNA-1)IgG。使用来自65例处于不同EBV疾病阶段患者的血清,与一致性参考结果相比,BioPlex对所有EBV标志物的检测结果显示出近乎完美的一致性。Architect对于VCA IgG和EBNA-1 IgG的检测结果近乎完美,对于VCA IgM的检测结果虽然有5个结果不明确,但也具有较高的一致性。由于我们医院的大多数检测来自EBNA-1 IgG结果为阳性的成人患者,基于EBNA的算法实施后的分析显示出优于三种血清学标志物并行检测的优势。这项小型验证表明,两种用于EBV血清学检测的自动化系统对所有EBV标志物都具有良好的性能,并且基于EBNA的检测算法对于成人医院来说是理想的。