Abstract

The relatively large pick-up volume of surface electrodes has for long motivated the concern that muscles other than that of interest may contribute to surface electromyograms (EMGs). Recent findings suggest however the pick-up volume of surface electrodes may be smaller than previously appreciated, possibly leading to the detection of surface EMGs insensitive to muscle activity. Here we combined surface and intramuscular recordings to investigate how comparably action potentials from gastrocnemius and soleus are represented in surface EMGs detected with different inter-electrode distances. We computed the firing instants of motor units identified from intramuscular EMGs detected from gastrocnemius and soleus while five participants stood upright. We used these instants to trigger and average surface EMGs detected from multiple skin regions along gastrocnemius. Results from 66 motor units (whereof 31 from gastrocnemius) revealed the surface-recorded amplitude of soleus action potentials was 6% of that of gastrocnemius and did not decrease for inter-electrode distances smaller than 4 cm. Gastrocnemius action potentials were more likely detected for greater inter-electrode distances and their amplitude increased steeply up to 5 cm inter-electrode distance. These results suggest that reducing inter-electrode distance excessively may result in the detection of surface EMGs insensitive to gastrocnemius activity without substantial attenuation of soleus crosstalk.

摘要

表面电极的相对较大的拾音器体积长期以来一直促使人们担心,除了感兴趣的肌肉之外,其他肌肉可能会对表面肌电图(EMG)产生影响。然而,最近的发现表明,表面电极的拾音器体积可能比以前认为的要小,这可能导致对肌肉活动不敏感的表面 EMG 的检测。在这里,我们结合表面和肌内记录来研究来自比目鱼肌和腓肠肌的动作电位如何在使用不同电极间距检测到的表面 EMG 中被相对表示。我们计算了从腓肠肌和比目鱼肌中检测到的肌内 EMG 中识别出的运动单位的触发瞬间,而五名参与者保持直立。我们使用这些瞬间来触发和平均从多个皮肤区域沿着比目鱼肌检测到的表面 EMG。来自 66 个运动单位(其中 31 个来自比目鱼肌)的结果表明,比目鱼肌动作电位的表面记录幅度是腓肠肌的 6%,并且当电极间距小于 4cm 时不会减小。对于更大的电极间距,更有可能检测到腓肠肌动作电位,并且其幅度在 5cm 电极间距处急剧增加。这些结果表明,过度减小电极间距可能导致检测到不敏感于腓肠肌活动的表面 EMG,而不会对面神经交叉的衰减有实质性的影响。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验