Hernández-Martínez Carmen, Palazón-Bru Antonio, Azrak Cesar, Navarro-Navarro Aída, Baeza-Díaz Manuel Vicente, Martínez-Toldos José Juan, Gil-Guillén Vicente Francisco
Ophthalmology Service, General Hospital of Elche, Elche, Alicante, Spain.
Department of Clinical Medicine, Miguel Hernández University, San Juan de Alicante, Alicante, Spain.
PeerJ. 2017 Oct 12;5:e3922. doi: 10.7717/peerj.3922. eCollection 2017.
In late 2015, cut-off points were published for foveal thickness to diagnose diabetic macular oedema taking into account the presence of intraretinal fluid using optical coherence tomography (OCT) in primary care patients (90 µm in the presence of intraretinal fluid and 310 µm otherwise).
This cross-sectional observational study was carried out on 134 eyes of diabetic patients treated in specialised ophthalmology services in a Spanish region in 2012-2013, to externally validate the aforementioned cut-off points. The main variable (Clinical Standard) was the diagnosis of macular oedema through indirect ophthalmoscopy and posterior segment slit-lamp biomicroscopy. As validation variables, both the foveal thickness and the presence of intraretinal fluid obtained by OCT were used. Validation was performed using bootstrapping by calculating the area under the ROC curve (AUC), sensitivity, specificity, positive likelihood ratio (PLR) and negative likelihood ratio (NLR).
Forty-one eyes presented diabetic macular oedema (30.6%). The bootstrapping validation parameters were: AUC, 0.88; sensitivity, 0.75; specificity, 0.95; PLR, 14.31; NLR, 0.26. These values were very similar to those of the original publication.
We have externally validated in specialised care patients the cut-off points published for the diagnosis of diabetic macular oedema. We suggest that others carry out validation studies in their communities.
2015年末,公布了针对初级保健患者使用光学相干断层扫描(OCT)诊断糖尿病性黄斑水肿时的黄斑中心凹厚度截断值,该截断值考虑了视网膜内液的存在情况(存在视网膜内液时为90μm,否则为310μm)。
2012 - 2013年,在西班牙某地区的专业眼科服务机构对134例糖尿病患者的眼睛进行了这项横断面观察性研究,以外部验证上述截断值。主要变量(临床标准)是通过间接检眼镜和后部节段裂隙灯生物显微镜检查诊断黄斑水肿。作为验证变量,使用了通过OCT获得的黄斑中心凹厚度和视网膜内液的存在情况。通过计算ROC曲线下面积(AUC)、敏感性、特异性、阳性似然比(PLR)和阴性似然比(NLR),采用自抽样法进行验证。
41只眼出现糖尿病性黄斑水肿(30.6%)。自抽样法验证参数为:AUC为0.88;敏感性为0.75;特异性为0.95;PLR为14.31;NLR为0.26。这些值与原始出版物中的值非常相似。
我们在专科护理患者中对公布的糖尿病性黄斑水肿诊断截断值进行了外部验证。我们建议其他人在其所在社区开展验证研究。