使用光学相干断层扫描技术对不同条件下的鼻内阀进行体内成像。

In vivo imaging of the internal nasal valve during different conditions using optical coherence tomography.

作者信息

Englhard Anna S, Wiedmann Maximilian, Ledderose Georg J, Lemieux Bryan, Badran Alan, Jing Joseph C, Chen Zhongping, Volgger Veronika, Wong Brian J F

机构信息

Department of Otolaryngology-Head and Neck Surgery, Ludwig Maximilian University of Munich, Munich, Germany.

Department of Biomedical Engineering, University of California, Irvine, Orange, California, U.S.A.

出版信息

Laryngoscope. 2018 Mar;128(3):E105-E110. doi: 10.1002/lary.26962. Epub 2017 Oct 17.

Abstract

OBJECTIVE

Previously, we proposed long-range optical coherence tomography (LR-OCT) to be an effective method for the quantitative evaluation of the nasal valve geometry. Here, the objective was to quantify the reduction in the internal nasal valve angle and cross-sectional area that results in subjective nasal airway obstruction and to evaluate the dynamic behavior of the valve during respiration using LR-OCT.

METHODS

For 16 healthy individuals, LR-OCT was performed in each naris during: 1) normal respiration, 2) peak forced inspiration, 3) lateral nasal wall depression (to the onset of obstructive symptoms), and 4) after application of a topical decongestant. The angle and the cross-sectional area of the valve were measured.

RESULTS

A reduction of the valve angle from 18.3° to 14.1° (11° in Caucasians and 17° in Asians) and a decrease of the cross-sectional area from 0.65 cm to 0.55 cm led to subjective nasal obstruction. Forceful breathing did not significantly change the internal nasal valve area in healthy individuals. Application of nasal decongestant resulted in increased values.

CONCLUSION

LR-OCT proved to be a fast and readily performed method for the evaluation of the dynamic behavior of the nasal valve. The values of the angle and the cross-sectional area of the valve were reproducible, and changes in size could be accurately delineated.

LEVEL OF EVIDENCE

2b. Laryngoscope, 128:E105-E110, 2018.

摘要

目的

此前,我们提出长程光学相干断层扫描(LR - OCT)是定量评估鼻瓣几何形态的有效方法。在此,目的是量化导致主观鼻气道阻塞的鼻内瓣膜角度和横截面积的减小,并使用LR - OCT评估呼吸过程中瓣膜的动态行为。

方法

对16名健康个体,在以下情况下对每个鼻孔进行LR - OCT检查:1)正常呼吸;2)用力吸气峰值;3)鼻侧壁凹陷(至出现阻塞症状);4)应用局部减充血剂后。测量瓣膜的角度和横截面积。

结果

瓣膜角度从18.3°减小至14.1°(白种人为11°,亚洲人为17°),横截面积从0.65平方厘米减小至0.55平方厘米会导致主观鼻阻塞。在健康个体中,用力呼吸并未显著改变鼻内瓣膜面积。应用鼻减充血剂后数值增加。

结论

LR - OCT被证明是评估鼻瓣动态行为的一种快速且易于实施的方法。瓣膜角度和横截面积的值具有可重复性,并且大小变化能够被准确描绘。