Suppr超能文献

Metasul金属对金属全髋关节置换术的长期临床结果:128例初次全髋关节置换术的12.6年随访

Long-term clinical results of the Metasul metal-on-metal total hip arthroplasty: 12.6 years follow-up of 128 primary total hip replacements.

作者信息

Zuiderbaan Hendrik A, Visser Dennis, Sierevelt Inger N, Penders Janine, Verhart Jeanette, Vergroesen Diederik A

机构信息

Department of Orthopaedic Surgery, Spaarne Gasthuis, Hoofddorp - The Netherlands.

出版信息

Hip Int. 2018 May;28(3):330-335. doi: 10.5301/hipint.5000574. Epub 2017 Oct 14.

Abstract

INTRODUCTION

The purpose of the present study is to report the long-term clinical results of an uncemented total hip arthroplasty (THA) using a Metasul metal-on-metal (MoM) 28-mm bearing and to evaluate the long-term serum cobalt levels.

METHODS

At an average of 12.6 years following primary THA, we retrospectively reviewed the clinical results of the first 116 consecutive patients (128 THAs) in our institution who underwent 28-mm Metasul MoM THA. Of the 78 patients who were able to visit our outpatient clinic, serum cobalt levels were evaluated.

RESULTS

The overall survival rate of the cohort was 96.1% (95% confidence interval [CI], 93.2-99.6), 12.6 years (95% CI, 12.3-12.7 years) following surgery. 3 patients had undergone revision due to aseptic loosening of the stem and 2 patients sustained a periprosthetic fracture. The average modified Harris Hip Score was 90 (72-97) and the average Oxford Hip Score was 56 (48-60), representing both excellent outcome scores. The average serum cobalt of the entire cohort was 20.1 nmol/L (range 8.5-227.7 nmol/L). Serum cobalt levels of patients with a bilateral MoM THA were significantly higher (35.0 nmol/l, p<0.01). No relation between serum cobalt levels, subjective outcome, radiolucent lines on radiographs and survivorship of the implant was noted.

CONCLUSIONS

Long-term results of the metasul MoM bearing articulation in THA seem to be excellent, although cobalt serum levels should be monitored closely.

摘要

引言

本研究的目的是报告使用Metasul金属对金属(MoM)28毫米轴承的非骨水泥型全髋关节置换术(THA)的长期临床结果,并评估长期血清钴水平。

方法

在初次THA平均12.6年后,我们回顾性分析了本机构连续接受28毫米Metasul MoM THA的前116例患者(128例THA)的临床结果。在78例能够到门诊就诊的患者中,评估了血清钴水平。

结果

该队列在术后12.6年(95%可信区间[CI],12.3 - 12.7年)的总生存率为96.1%(95% CI,93.2 - 99.6)。3例患者因假体柄无菌性松动接受了翻修,2例患者发生了假体周围骨折。平均改良Harris髋关节评分90分(72 - 97分),平均牛津髋关节评分56分(48 - 60分),均代表优良的结果评分。整个队列的平均血清钴水平为20.1 nmol/L(范围8.5 - 227.7 nmol/L)。双侧MoM THA患者的血清钴水平显著更高(35.0 nmol/l,p<0.01)。未发现血清钴水平、主观结果、X线片上的透光线与假体生存率之间存在关联。

结论

THA中Metasul MoM轴承关节的长期结果似乎良好,尽管应密切监测血清钴水平。