Suppr超能文献

DIAGNOdent与数字X线摄影术检测复合树脂修复体邻面继发龋诊断准确性的体外比较

In Vitro Comparison of Diagnostic Accuracy of DIAGNOdent and Digital Radiography for Detection of Secondary Proximal Caries Adjacent to Composite Restorations.

作者信息

Ghoncheh Zahra, Zonouzy Zahra, Kiomarsi Nazanin, Kharazifar Mohammad Javad, Chiniforush Nasim

机构信息

Department of Oral and Maxillofacial Radiology, Dental faculty, Tehran University of Medical Sciences, International Campus, Tehran, Iran.

Tehran University of Medical Sciences, International Campus, Tehran, Iran.

出版信息

J Lasers Med Sci. 2017 Fall;8(4):172-176. doi: 10.15171/jlms.2017.31. Epub 2017 Sep 27.

Abstract

Early detection of secondary proximal caries is critical for the preservation of tooth vitality. This study sought to assess and compare the diagnostic accuracy of DIAGNOdent and digital radiography for detection of secondary proximal caries adjacent to composite restorations. Sixty extracted molars including 30 teeth with carious lesions and 30 sound teeth were randomly selected. Class II cavities were prepared in all teeth and carious dentin was intentionally left in the gingival floor of cavities in 30 carious teeth. All cavities were restored with composite resin. The teeth were mounted in wax blocks (three teeth per block) and examined for caries using (DIAGNOdent kaVo Dental, Biberach, Germany). Digital radiographs using DIGORA photostimulable phosphor (PSP) plates (Soredex Corporation, Helsinki, Finland) were obtained from all teeth using the parallel technique and were evaluated by 4 observers. Repeated measure analysis of variance (ANOVA) was applied to calculate sensitivity and specificity values of the two diagnostic techniques. Receiver operating characteristic (ROC) curve was plotted for DIAGNOdent results and based on that, the cutoff points were determined. The sensitivity and specificity values at the cut-off point of 10.5 were 0.622±0.038 and 0.822±0.077 for DIAGNOdent and 0.591±0.093 and 0.891±0.083 for digital radiography, respectively. The area under the ROC curve was 0.7 for DIAGNOdent. Weighted kappa revealed moderate to almost perfect intra-observer agreement (0.46-0.99). Intraclass correlation coefficient (ICC) for DIAGNOdent was calculated to be 0.88. No statistically significant difference was noted in diagnostic accuracy of DIAGNOdent and digital radiography for detection of secondary proximal caries adjacent to composite restorations. Thus, DIAGNOdent may be used as an adjunct diagnostic tool for detection of secondary proximal caries beneath composite restorations.

摘要

早期发现继发邻面龋对于保存牙齿活力至关重要。本研究旨在评估和比较DIAGNOdent和数字放射成像在检测复合树脂修复体邻面继发龋方面的诊断准确性。随机选取60颗拔除的磨牙,其中30颗有龋损牙齿,30颗健康牙齿。所有牙齿均制备Ⅱ类洞型,30颗龋损牙齿的洞型龈壁特意保留龋坏牙本质。所有洞型均用复合树脂修复。将牙齿固定在蜡块中(每块3颗牙齿),使用DIAGNOdent kaVo Dental(德国比伯拉赫)检查龋齿情况。使用DIGORA光激励荧光板(PSP)(芬兰赫尔辛基Soredex公司),采用平行投照技术对所有牙齿获取数字根尖片,并由4名观察者进行评估。应用重复测量方差分析(ANOVA)计算两种诊断技术的敏感度和特异度值。绘制DIAGNOdent结果的受试者工作特征(ROC)曲线,并据此确定截断点。在截断点为10.5时,DIAGNOdent的敏感度和特异度值分别为0.622±0.038和0.822±0.077,数字放射成像的敏感度和特异度值分别为0.591±0.093和0.891±0.083。DIAGNOdent的ROC曲线下面积为0.7。加权kappa显示观察者内一致性从中度到几乎完美(0.46 - 0.99)。DIAGNOdent的组内相关系数(ICC)计算为0.88。在检测复合树脂修复体邻面继发龋方面,DIAGNOdent和数字放射成像的诊断准确性无统计学显著差异。因此,DIAGNOdent可作为检测复合树脂修复体下方继发邻面龋的辅助诊断工具。

相似文献

引用本文的文献

本文引用的文献

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验