Ohlson L
Department of Radiology, Karolinska Hospital, Stockholm, Sweden.
Radiology. 1989 Jan;170(1 Pt 1):33-7. doi: 10.1148/radiology.170.1.2909118.
In 21 of 636 patients with normal renal function and without obstruction of the upper urinary tract, urograms showed that contrast medium filled thin cylindrical structures in the renal pyramids with the same course as that of the collecting ducts. The prevalence of cylinders when the low-osmolality contrast medium iohexol was used was 21 of 158 studies (13.3%) and with the high-osmolality contrast medium amidotrizoate, two of 529 studies (0.4%). The cylinders were more distinct and more numerous with iohexol, while with amidotrizoate most cylinders appeared as striations. The cylinders appeared within 4 minutes from the start of contrast medium injection and remained distinct for 35-50 minutes. The diameter of the cylinders varied between 0.05 and 0.30 mm; their course was almost straight and closely followed the shape of the pyramid. The cylinders proved to consist of the highly opacified collecting duct lumina. Their configuration indicated that a single cylinder might be an individual collecting duct, but conclusive evidence was lacking.
在636例肾功能正常且上尿路无梗阻的患者中,有21例患者的尿路造影显示造影剂充盈肾锥体中的细圆柱状结构,其走行与集合管相同。使用低渗造影剂碘海醇时,圆柱状结构的发生率为158例研究中的21例(13.3%);使用高渗造影剂泛影葡胺时,529例研究中有2例(0.4%)出现圆柱状结构。碘海醇造影时圆柱状结构更清晰、数量更多,而使用泛影葡胺时多数圆柱状结构表现为条纹状。圆柱状结构在注射造影剂开始后4分钟内出现,35 - 50分钟内仍清晰可见。圆柱状结构的直径在0.05至0.30毫米之间;其走行几乎是直的,紧密跟随锥体的形状。圆柱状结构经证实由高度显影的集合管管腔组成。其形态表明单个圆柱状结构可能是单个集合管,但缺乏确凿证据。