Suppr超能文献

线性位置传感器和加速度计测量冲拳特征的同时效度和信度。

Concurrent Validity and Reliability of a Linear Positional Transducer and an Accelerometer to Measure Punch Characteristics.

机构信息

School of Allied Health Sciences and Menzies Health Institute Queensland, Griffith University, Gold Coast, Queensland, Australia.

The Bone Clinic, Brisbane, Queensland, Australia.

出版信息

J Strength Cond Res. 2018 Mar;32(3):675-680. doi: 10.1519/JSC.0000000000002284.

Abstract

Lambert, C, Beck, BR, and Weeks, BK. Concurrent validity and reliability of a linear positional transducer and an accelerometer to measure punch characteristics. J Strength Cond Res 32(3): 675-680, 2018-Punch speed is an important factor in the sport of boxing, and its measurement has important implications for monitoring training progression and outcomes. The aim of the current study was to establish the concurrent validity and reliability of a linear positional transducer and an accelerometer for the quantification of punch characteristics in untrained adults. Men and women aged 18-30 years with no previous boxing experience and no upper-limb musculoskeletal injuries were recruited. Participants performed 6 straight right punches; 3 at a self-determined 50% effort; and 3 at maximum effort. An accelerometer (Crossbow) and a linear positional transducer (GymAware) were used to examine peak velocity and acceleration of each punch. Validity was examined using Pearson's correlation analyses and by calculating mean bias and limits of agreement between measures from each device, whereas reliability was established using intraclass correlation coefficients (ICCs). Forty-four healthy young adults (28M and 16F; age 22.2 ± 2.9 years) participated. Moderate-to-strong positive associations were observed for both devices at 50% effort for velocity (r = 0.572-0.696) and acceleration (r = 0.867-0.921) and at maximum effort for velocity (r = 0.748-0.781) and acceleration (r = 0.897-0.946). High levels of reliability were observed with maximum punches for both devices (ICC = 0.922-0.981). Overall, moderate-strong measurement validity and reliability for punch speed was observed between the accelerometer and GymAware. Thus, the GymAware linear positional transducer is an acceptable measurement tool for the quantification of punch speed for straight punches in untrained adults.

摘要

兰伯特、C、贝克、BR 和威克斯、BK。线性位置传感器和加速度计测量冲拳特征的同时效度和信度。J 力量与条件研究 32(3):675-680,2018-冲拳速度是拳击运动的一个重要因素,其测量对于监测训练进展和结果具有重要意义。本研究的目的是确定线性位置传感器和加速度计在量化未经训练的成年人冲拳特征方面的同时效度和信度。招募了年龄在 18-30 岁之间、没有拳击经验且上肢无肌肉骨骼损伤的男性和女性。参与者进行了 6 次直右拳;3 次自我决定的 50%力量;3 次最大力量。使用加速度计(十字弓)和线性位置传感器(GymAware)来检测每一拳的最大速度和加速度。使用 Pearson 相关分析和计算每个设备测量值之间的平均偏差和协议界限来检查有效性,而使用组内相关系数(ICC)来确定可靠性。44 名健康的年轻人(28 名男性和 16 名女性;年龄 22.2±2.9 岁)参加了研究。在 50%的力量下,两种设备对速度(r = 0.572-0.696)和加速度(r = 0.867-0.921),以及在最大力量下对速度(r = 0.748-0.781)和加速度(r = 0.897-0.946)都有中等至强的正相关。两种设备在最大力量下的冲拳速度均表现出高度的可靠性(ICC = 0.922-0.981)。总的来说,在加速度计和 GymAware 之间观察到了冲拳速度的中度至强测量有效性和可靠性。因此,GymAware 线性位置传感器是一种可接受的测量工具,可用于量化未经训练的成年人直拳的冲拳速度。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验