Menzies Health Institute, Brisbane, QLD, Australia; Epworth Monash Rehabilitation Medicine Unit Epworth HealthCare, Melbourne, VIC, Australia.
Epworth Monash Rehabilitation Medicine Unit Epworth HealthCare, Melbourne, VIC, Australia.
Arch Phys Med Rehabil. 2018 Apr;99(4):629-634. doi: 10.1016/j.apmr.2017.10.015. Epub 2017 Nov 6.
To evaluate reproducibility (reliability and agreement) of the Brachial Assessment Tool (BrAT), a new patient-reported outcome measure for adults with traumatic brachial plexus injury (BPI).
Prospective repeated-measure design.
Outpatient clinics.
Adults with confirmed traumatic BPI (N=43; age range, 19-82y).
People with BPI completed the 31-item 4-response BrAT twice, 2 weeks apart. Results for the 3 subscales and summed score were compared at time 1 and time 2 to determine reliability, including systematic differences using paired t tests, test retest using intraclass correlation coefficient model 1,1 (ICC), and internal consistency using Cronbach α. Agreement parameters included standard error of measurement, minimal detectable change, and limits of agreement.
BrAT.
Test-retest reliability was excellent (ICC=.90-.97). Internal consistency was high (Cronbach α=.90-.98). Measurement error was relatively low (standard error of measurement range, 3.1-8.8). A change of >4 for subscale 1, >6 for subscale 2, >4 for subscale 3, and >10 for the summed score is indicative of change over and above measurement error. Limits of agreement ranged from ±4.4 (subscale 3) to 11.61 (summed score).
These findings support the use of the BrAT as a reproducible patient-reported outcome measure for adults with traumatic BPI with evidence of appropriate reliability and agreement for both individual and group comparisons. Further psychometric testing is required to establish the construct validity and responsiveness of the BrAT.
评估 Brachial Assessment Tool(BrAT)的可重复性(可靠性和一致性),这是一种用于评估成人创伤性臂丛神经损伤(BPI)的新的患者报告结局测量工具。
前瞻性重复测量设计。
门诊诊所。
确诊为创伤性 BPI 的成年人(N=43;年龄范围 19-82 岁)。
BPI 患者在 2 周内两次完成 31 项 4 项反应 BrAT。在时间 1 和时间 2 比较 3 个子量表和总分的结果,以确定可靠性,包括使用配对 t 检验的系统差异、使用 ICC 模型 1,1(ICC)的测试再测试和使用 Cronbach α 的内部一致性。一致性参数包括测量误差、最小可检测变化和界限协议。
BrAT。
测试 - 再测试可靠性非常好(ICC=.90-.97)。内部一致性很高(Cronbach α=.90-.98)。测量误差相对较低(测量误差范围,3.1-8.8)。子量表 1 的变化>4、子量表 2 的变化>6、子量表 3 的变化>4 以及总分的变化>10 表明变化超过了测量误差。协议范围从±4.4(子量表 3)到 11.61(总分)。
这些发现支持使用 BrAT 作为一种可重复的患者报告结局测量工具,用于评估成人创伤性 BPI,具有适当的可靠性和一致性,适用于个体和组比较。需要进一步的心理测量测试来确定 BrAT 的结构有效性和反应性。