Suppr超能文献

个人粉尘监测仪和个人数据 RAM 测量的可吸入质量浓度与重量测量的比较。

Comparison of Respirable Mass Concentrations Measured by a Personal Dust Monitor and a Personal DataRAM to Gravimetric Measurements.

机构信息

Department of Chemical and Biochemical Engineering, University of Iowa, Iowa City, Iowa, USA.

Department of Occupational and Environmental Health, University of Iowa, Iowa City, Iowa, USA.

出版信息

Ann Work Expo Health. 2017 Dec 15;62(1):62-71. doi: 10.1093/annweh/wxx083.

Abstract

In 2016, the Mine Safety and Health Administration required the use of continuous monitors to measure respirable dust in mines and better protect miner health. The Personal Dust Monitor, PDM3700, has met stringent performance criteria for this purpose. In a laboratory study, respirable mass concentrations measured with the PDM3700 and a photometer (personal DataRam, pDR-1500) were compared to those measured gravimetrically for five aerosols of varying refractive index and density (diesel exhaust fume, welding fume, coal dust, Arizona road dust (ARD), and salt [NaCl] aerosol) at target concentrations of 0.38, 0.75, and 1.5 mg m-3. For all aerosols except coal dust, strong, near-one-to-one, linear relationships were observed between mass concentrations measured with the PDM3700 and gravimetrically (diesel fume, slope = 0.99, R2 = 0.99; ARD, slope = 0.98, R2 = 0.99; and NaCl, slope = 0.95, R2 = 0.99). The slope deviated substantially from unity for coal dust (slope = 0.55; R2 = 0.99). Linear relationships were also observed between mass concentrations measured with the pDR-1500 and gravimetrically, but one-to-one behavior was not exhibited (diesel fume, slope = 0.23, R2 = 0.76; coal dust, slope = 0.54, R2 = 0.99; ARD, slope = 0.61, R2 = 0.99; NaCl, slope = 1.14, R2 = 0.98). Unlike the pDR-1500, mass concentrations measured with the PDM3700 appear independent of refractive index and density, suggesting that it could have applications in a variety of occupational settings.

摘要

2016 年,美国矿山安全与健康管理局要求在矿山使用连续监测仪来测量可呼吸性粉尘,以更好地保护矿工健康。个人粉尘监测仪 PDM3700 满足了这一目的的严格性能标准。在一项实验室研究中,使用 PDM3700 和光度计(个人 DataRam,pDR-1500)测量的可呼吸性质量浓度与重力测量的五种不同折射率和密度的气溶胶(柴油机废气、焊接烟尘、煤尘、亚利桑那州道路粉尘(ARD)和盐[NaCl]气溶胶)的质量浓度进行了比较,目标浓度为 0.38、0.75 和 1.5mg/m3。除了煤尘外,对于所有气溶胶,PDM3700 测量的质量浓度与重力测量的质量浓度之间都存在强烈的、近乎一一对应的线性关系(柴油机废气,斜率=0.99,R2=0.99;ARD,斜率=0.98,R2=0.99;NaCl,斜率=0.95,R2=0.99)。煤尘的斜率与 1 有很大偏差(斜率=0.55;R2=0.99)。pDR-1500 测量的质量浓度与重力测量的质量浓度之间也存在线性关系,但没有表现出一一对应的关系(柴油机废气,斜率=0.23,R2=0.76;煤尘,斜率=0.54,R2=0.99;ARD,斜率=0.61,R2=0.99;NaCl,斜率=1.14,R2=0.98)。与 pDR-1500 不同,PDM3700 测量的质量浓度似乎与折射率和密度无关,这表明它可能在各种职业环境中得到应用。

相似文献

6
Testing a revised inlet for the personal dust monitor.个人粉尘监测器进气口的改良测试。
J Occup Environ Hyg. 2019 Mar;16(3):242-249. doi: 10.1080/15459624.2019.1566732. Epub 2019 Feb 22.
10

引用本文的文献

本文引用的文献

7
Occupational health hazards in mining: an overview.采矿业中的职业健康危害:概述
Occup Med (Lond). 2004 Aug;54(5):283-9. doi: 10.1093/occmed/kqh072.