采用一种基于质量控制的新剂量调查方法确定伊朗计算机断层扫描检查中的国家诊断参考水平

DETERMINATION OF NATIONAL DIAGNOSTIC REFERENCE LEVELS IN COMPUTED TOMOGRAPHY EXAMINATIONS OF IRAN BY A NEW QUALITY CONTROL-BASED DOSE SURVEY METHOD.

作者信息

Sohrabi Mehdi, Parsi Masoumeh, Mianji Fereidoun

机构信息

Health Physics and Dosimetry Research Laboratory, Department of Energy Engineering and Physics, Amirkabir University of Technology, Tehran, Iran.

Nuclear Science and Technology Research Institute, Tehran, Iran.

出版信息

Radiat Prot Dosimetry. 2018 May 1;179(3):206-215. doi: 10.1093/rpd/ncx252.

Abstract

National diagnostic reference levels (NDRLs) of Iran were determined for the four most common CT examinations including head, sinus, chest and abdomen/pelvis. A new 'quality control (QC)-based dose survey method', as developed by us, was applied to 157 CT scanners in Iran (2014-15) with different slice classes, models and geographic spread across the country. The NDRLs for head, sinus, chest and abdomen/pelvis examinations are 58, 29, 12 and 14 mGy for CTDIVol and 750, 300, 300 and 650 mGy.cm for DLP, respectively. The 'QC-based dose survey method' was further proven that it is a simple, accurate and practical method for a time and cost-effective NDRLs determination. One effective approach for optimization of the CT examination protocols at the national level is the provision of an adequate standardized training of the radiologists, technicians and medical physicists on the patient radiation protection principles and implementation of the DRL concept in clinical practices.

摘要

伊朗确定了四种最常见CT检查(包括头部、鼻窦、胸部和腹部/盆腔)的国家诊断参考水平(NDRLs)。我们开发的一种新的“基于质量控制(QC)的剂量调查方法”,应用于2014 - 2015年伊朗的157台CT扫描仪,这些扫描仪具有不同的切片类别、型号且分布在全国各地。头部、鼻窦、胸部和腹部/盆腔检查的CTDIvol的NDRLs分别为58、29、12和14 mGy,DLP的NDRLs分别为750、300、300和650 mGy.cm。“基于QC的剂量调查方法”进一步证明,它是一种简单、准确且实用的方法,可用于高效且经济地确定NDRLs。在国家层面优化CT检查方案的一种有效方法是为放射科医生、技术人员和医学物理学家提供关于患者辐射防护原则以及在临床实践中实施DRL概念的充分标准化培训。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验