State Key Laboratory of Marine Environmental Science, College of the Environment and Ecology, Xiamen University, Xiamen 361102, China.
State Key Laboratory of Marine Environmental Science, College of the Environment and Ecology, Xiamen University, Xiamen 361102, China.
Talanta. 2018 Feb 1;178:577-582. doi: 10.1016/j.talanta.2017.09.073. Epub 2017 Sep 28.
A sensitive and precise method for determination of nanomolar manganese in seawater was developed, using reverse flow injection analysis, a long path length liquid waveguide capillary cell, and spectrophotometric detection. The reaction was based on manganese catalyzed oxidation of leucomalachite green with sodium periodate. Various experimental parameters were investigated and optimized. Foreign trace metal ions of iron, copper, zinc, nickel and aluminum did not cause obvious interference with manganese detection. Low manganese seawater was prepared and used as the blank and standards' matrix, to eliminate the seawater matrix effect. The method detection limit was 0.20nmolL, and the quantification range was 0.50-10.00nmolL, which should be sensitive enough and suitable for open ocean seawater analysis. The seawater certified reference material NASS-6 was used to test the accuracy, and good agreement was obtained. The proposed method was applied to analyze seawater samples collected at the SEATS station in the South China Sea. The vertical profile of the total dissolvable manganese is reported and discussed.
建立了一种灵敏、精确的测定海水中痕量锰的方法,采用反向流动注射分析、长光程液芯波导毛细管池和分光光度检测。该反应基于锰催化高碘酸钠氧化隐色孔雀绿。研究并优化了各种实验参数。铁、铜、锌、镍和铝等外来痕量金属离子对锰的检测没有明显干扰。用低锰海水作为空白和标准品的基体,以消除海水基体效应。该方法的检出限为 0.20nmol/L,定量范围为 0.50-10.00nmol/L,灵敏度足够高,适用于开阔大洋海水分析。采用海水标准物质 NASS-6 进行准确度测试,结果吻合良好。该方法已应用于分析南海 SEATS 站采集的海水样品。报道并讨论了总可溶解锰的垂直分布。