健康成年人在基于跑步机的自定步速虚拟现实步行过程中步态参数的评分者内重复性。

Intra-rater repeatability of gait parameters in healthy adults during self-paced treadmill-based virtual reality walking.

作者信息

Al-Amri Mohammad, Al Balushi Hilal, Mashabi Abdulrhman

机构信息

a School of Healthcare Sciences, College of Biomedical and Life Sciences Cardiff University , Cardiff , UK .

b Arthritis Research UK Biomechanics and Bioengineering Centre , Cardiff University , Cardiff , UK.

出版信息

Comput Methods Biomech Biomed Engin. 2017 Dec;20(16):1669-1677. doi: 10.1080/10255842.2017.1404994. Epub 2017 Nov 23.

Abstract

Self-paced treadmill walking is becoming increasingly popular for the gait assessment and re-education, in both research and clinical settings. Its day-to-day repeatability is yet to be established. This study scrutinised the test-retest repeatability of key gait parameters, obtained from the Gait Real-time Analysis Interactive Lab (GRAIL) system. Twenty-three male able-bodied adults (age: 34.56 ± 5.12 years) completed two separate gait assessments on the GRAIL system, separated by 5 ± 3 days. Key gait kinematic, kinetic, and spatial-temporal parameters were analysed. The Intraclass-Correlation Coefficients (ICC), Standard Error Measurement (SEM), Minimum Detectable Change (MDC), and the 95% limits of agreements were calculated to evaluate the repeatability of these gait parameters. Day-to-day agreements were excellent (ICCs > 0.87) for spatial-temporal parameters with low MDC and SEM values, <0.153 and <0.055, respectively. The repeatability was higher for joint kinetic than kinematic parameters, as reflected in small values of SEM (<0.13 Nm/kg and <3.4°) and MDC (<0.335 Nm/kg and <9.44°). The obtained values of all parameters fell within the 95% limits of agreement. Our findings demonstrate the repeatability of the GRAIL system available in our laboratory. The SEM and MDC values can be used to assist researchers and clinicians to distinguish 'real' changes in gait performance over time.

摘要

在研究和临床环境中,自定步速的跑步机行走在步态评估和再训练方面越来越受欢迎。但其日常可重复性尚未得到证实。本研究仔细审查了从步态实时分析交互式实验室(GRAIL)系统获得的关键步态参数的重测可重复性。23名身体健康的成年男性(年龄:34.56±5.12岁)在GRAIL系统上完成了两次独立的步态评估,两次评估间隔5±3天。分析了关键的步态运动学、动力学和时空参数。计算了组内相关系数(ICC)、标准误差测量(SEM)、最小可检测变化(MDC)以及95%一致性界限,以评估这些步态参数的可重复性。对于时空参数,日常一致性极佳(ICC>0.87),MDC和SEM值较低,分别<0.153和<0.055。关节动力学参数的可重复性高于运动学参数,这体现在SEM(<0.13 Nm/kg和<3.4°)和MDC(<0.335 Nm/kg和<9.44°)的较小值上。所有参数的获得值均落在95%一致性界限内。我们的研究结果证明了我们实验室中GRAIL系统的可重复性。SEM和MDC值可用于帮助研究人员和临床医生区分步态表现随时间的“真实”变化。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验