Stock E, Paepe D, Daminet S, Vandermeulen E, Duchateau L, Saunders J H, Vanderperren K
Department of Medical Imaging of Domestic Animals, Faculty of Veterinary Medicine, Ghent University, Merelbeke, Belgium.
Small Animal Department, Faculty of Veterinary Medicine, Ghent University, Merelbeke, Belgium.
J Vet Intern Med. 2018 Jan;32(1):260-266. doi: 10.1111/jvim.14869. Epub 2017 Nov 24.
Contrast-enhanced ultrasound examination (CEUS) is a functional imaging technique allowing noninvasive assessment of tissue perfusion. Studies in humans show that the technique holds great potential to be used in the diagnosis of chronic kidney disease (CKD). However, data in veterinary medicine are currently lacking.
To evaluate renal perfusion using CEUS in cats with CKD.
Fourteen client-owned cats with CKD and 43 healthy control cats.
Prospective case-controlled clinical trial using CEUS to evaluate renal perfusion in cats with CKD compared to healthy control cats. Time-intensity curves were created, and perfusion parameters were calculated using off-line software. A linear mixed model was used to examine differences between perfusion parameters of cats with CKD and healthy cats.
In cats with CKD, longer time to peak and shorter mean transit times were observed for the renal cortex. In contrast, a shorter time to peak and rise time were seen for the renal medulla. The findings for the renal cortex indicate decreased blood velocity and shorter total duration of enhancement, likely caused by increased vascular resistance in CKD. Increased blood velocity in the renal medulla has not been described before and may be because of a different response to regulatory factors in cortex and medulla.
Contrast-enhanced ultrasound examination was capable of detecting perfusion changes in cats with CKD. Further research is warranted to assess the diagnostic capabilities of CEUS in early stage of the disease process.
超声造影检查(CEUS)是一种功能成像技术,可对组织灌注进行无创评估。人体研究表明,该技术在慢性肾脏病(CKD)诊断中具有巨大应用潜力。然而,目前兽医学领域的数据尚缺乏。
使用CEUS评估患有CKD的猫的肾脏灌注情况。
14只客户拥有的患有CKD的猫和43只健康对照猫。
采用前瞻性病例对照临床试验,使用CEUS评估患有CKD的猫与健康对照猫的肾脏灌注情况。绘制时间-强度曲线,并使用离线软件计算灌注参数。采用线性混合模型检查患有CKD的猫与健康猫灌注参数之间的差异。
在患有CKD的猫中,肾皮质的达峰时间更长,平均通过时间更短。相比之下,肾髓质的达峰时间和上升时间更短。肾皮质的这些发现表明血流速度降低,增强的总持续时间缩短,这可能是由于CKD中血管阻力增加所致。肾髓质血流速度增加此前未见报道,可能是因为皮质和髓质对调节因子的反应不同。
超声造影检查能够检测出患有CKD的猫的灌注变化。有必要进一步研究以评估CEUS在疾病早期阶段的诊断能力。