兔模型中斜行钢板对长骨扭转生长的调节作用

Torsional Growth Modulation of Long Bones by Oblique Plating in a Rabbit Model.

作者信息

Lazarus David E, Farnsworth Christine L, Jeffords Megan E, Marino Nikolas, Hallare Jericho, Edmonds Eric W

机构信息

Division of Orthopedic Surgery, Rady Children's Hospital.

Department of Bioengineering.

出版信息

J Pediatr Orthop. 2018 Feb;38(2):e97-e103. doi: 10.1097/BPO.0000000000001106.

Abstract

BACKGROUND

There is evidence that oblique tension band plating can affect torsional growth in long bones. This study sought to determine if the torsional growth could be modulated based on the angles of the tension band plating and whether or not oblique plating affected overall longitudinal growth.

METHODS

New Zealand White rabbits (10.5 wk old) had one screw placed on the metaphyseal side and one on the epiphyseal side of both medial and lateral sides of the right knee distal femoral physis. The sham group (n=5) included screw placement only. For the plate group (n=13), unlocked plates, angled from 0 to 76 degrees, connected the screws and spanned the physis. Radiographs were taken at biweekly intervals. After 6 weeks of growth, hindlimbs were harvested and microCT scans performed. Femoral length, distances between screw heads and angle between the plates were measured on radiographs. Femoral length differences were compared between groups. Femoral version was measured from 3D microCT. Plate angle changes were correlated to the difference in femoral version between limbs using Pearson correlation (significance was set to P<0.05 for all comparisons).

RESULTS

Femur length difference between the contralateral and the operative side was significantly greater in the plate group compared with the sham group over time (P=0.049). Medial and lateral screw distances changed significantly more in the sham group than the plate group on both sides (P<0.001). A greater initial angle between plates resulted in a greater change in the angle between plates (P<0.001). Significant correlations were found between right-left side femoral version differences and initial plate angle (P=0.003) and plate angle change (P=0.014).

CONCLUSIONS

The torsional effect of oblique plating seems to correlate with the amount of initial plate angle, with an additional, not negligible, longitudinal growth effect.

CLINICAL SIGNIFICANCE

Placing plates at given angles across open physes may result in predictable changes in bone torsion allowing for a safer and less invasive option when treating childhood torsional deformities, but the resulting shortening of the ipsilateral femur must be considered.

摘要

背景

有证据表明,斜向张力带钢板固定会影响长骨的扭转生长。本研究旨在确定扭转生长是否可根据张力带钢板的角度进行调节,以及斜向钢板固定是否会影响整体纵向生长。

方法

选用10.5周龄的新西兰白兔,在右膝股骨远端骨骺板的内侧和外侧的干骺端侧和骨骺侧各置入一枚螺钉。假手术组(n = 5)仅进行螺钉置入。钢板组(n = 13)使用角度从0度到76度的非锁定钢板连接螺钉并跨越骨骺板。每两周拍摄一次X线片。生长6周后,收获后肢并进行显微CT扫描。在X线片上测量股骨长度、螺钉头之间的距离以及钢板之间的角度。比较各组之间的股骨长度差异。从三维显微CT测量股骨扭转角。使用Pearson相关性分析将钢板角度变化与双下肢股骨扭转角差异进行关联(所有比较的显著性设定为P<0.05)。

结果

随着时间推移,钢板组对侧与手术侧的股骨长度差异明显大于假手术组(P = 0.049)。双侧假手术组的内侧和外侧螺钉距离变化明显大于钢板组(P<0.001)。钢板之间的初始角度越大,钢板之间角度的变化越大(P<0.001)。发现左右侧股骨扭转角差异与初始钢板角度(P = 0.003)和钢板角度变化(P = 0.014)之间存在显著相关性。

结论

斜向钢板固定的扭转效应似乎与初始钢板角度大小相关,同时还存在不可忽视的纵向生长效应。

临床意义

以特定角度放置钢板跨越开放的骨骺板可能会导致可预测的骨扭转变化,在治疗儿童扭转畸形时提供更安全、侵入性更小的选择,但必须考虑同侧股骨由此导致的缩短。