Anusha Bander, Madhusudhana Koppolu, Chinni Suneel Kumar, Paramesh Yelloji
Postgraduate Student, Department of Conservative Dentistry and Endodontics, Narayana Dental College and Hospital, Nellore, Andhra Pradesh, India.
Professor and Head, Department of Conservative Dentistry and Endodontics, Narayana Dental College and Hospital, Nellore, Andhra Pradesh, India.
J Clin Diagn Res. 2017 Sep;11(9):ZC36-ZC39. doi: 10.7860/JCDR/2017/28322.10572. Epub 2017 Sep 1.
Diagnosis of pulpal inflammation is a key to endodontics. Pulse oximetry is a true vitality testing device which relies on oxygen saturation levels of pulp and helps in diagnosis of different pulpal conditions.
The aim of the study was to analyse oxygen saturation levels of different pulpally inflamed teeth by using pulse oximetry.
Hundred patients were included in the study and categorized into five groups based on pulpal status of the test tooth by using heat test and cold test. Twenty patients were recruited in each of the experimental groups i.e., Reversible Pulpitis (RP), Irreversible Pulpitis (IP), Pulpal Necrosis (PN), Positive Control (PC, healthy teeth), and Negative Control (NC, endodontically treated teeth). Oxygen saturation levels of all the groups were measured along with each patient index finger oxygen saturation readings. Results were analysed by using ANOVA and Tukey HSD tests.
The mean oxygen saturation levels of RP, IP, PN, PC and NC were 85.4%, 81.6%, 70.7%, 94.6% and 0 respectively. There was significant difference in the oxygen saturation levels between all the groups.
Pulse oximeter is an effective tool in diagnosing different pulpal pathologies especially PN which was interpreted inaccurately by thermal tests.
牙髓炎症的诊断是牙髓病学的关键。脉搏血氧饱和度测定仪是一种真正的活力测试设备,它依赖于牙髓的氧饱和度水平,有助于诊断不同的牙髓状况。
本研究的目的是通过使用脉搏血氧饱和度测定仪分析不同牙髓炎症牙齿的氧饱和度水平。
本研究纳入了100名患者,并根据测试牙齿的牙髓状况,通过热测试和冷测试将其分为五组。每个实验组招募20名患者,即可复性牙髓炎(RP)、不可复性牙髓炎(IP)、牙髓坏死(PN)、阳性对照(PC,健康牙齿)和阴性对照(NC,根管治疗后的牙齿)。测量所有组的氧饱和度水平以及每位患者食指的氧饱和度读数。结果采用方差分析和Tukey HSD检验进行分析。
RP、IP、PN、PC和NC组的平均氧饱和度水平分别为85.4%、81.6%、70.7%、94.6%和0。所有组之间的氧饱和度水平存在显著差异。
脉搏血氧饱和度测定仪是诊断不同牙髓病变的有效工具,尤其是牙髓坏死,而热测试对其诊断不准确。