Comparison of the efficacy of a custom-made pulse oximeter probe with digital electric pulp tester, cold spray, and rubber cup for assessing pulp vitality.

机构信息

Dental Research Center, Faculty of Dentistry, Mashhad University of Medical Sciences, Mashhad, Iran.

出版信息

J Endod. 2012 Sep;38(9):1182-6. doi: 10.1016/j.joen.2012.06.012. Epub 2012 Jul 12.

Abstract

INTRODUCTION

The ideal technique for the evaluation of pulp vitality should be noninvasive, painless, objective, reliable, and reproducible. To achieve this, the most routine tests are sensitivity tests. However, a major shortcoming with these tests is that they indirectly indicate pulp vitality by measuring a neural response. Pulse oximetry is a well-established oxygen saturation monitoring technique broadly used in medicine. However, its efficacy as the pulp vitality test should be evaluated. The aim of this study was to design and build a custom-made pulse oximeter dental probe and to evaluate its efficacy in comparison with electric pulp tester, cold spray, and a rubber cup in pulp vitality testing.

METHODS

Twenty-four single-canal mandibular premolars needing endodontic treatment were selected. The patients did not have systemic disease and did not consume drugs. Also, they had no clinically relevant signs of necrosis. The selected teeth were pulpally tested with 4 kinds of tests including pulse oximetry, the electric test, cold spray, and the rubber cup. After endodontic treatment of these teeth, which revealed the actual status of the pulp, the results were analyzed by the kappa test to show the efficacy of these tests.

RESULTS

When comparing electric, cold, heat, and pulse oximeter tests with the gold standard, the kappa agreement coefficient was 18%, 18%, 14%, and 91%, respectively. The sensitivity of pulse oximetry, a rubber cup, electric test, and cold spray was 0.93, 0.60, 0.60, and 0.53, respectively. The specificity of these tests was 1.00, 0.55, 0.22, and 0.66, respectively.

CONCLUSIONS

Pulp testing by using pulse oximetry is more reliable than the electric test, rubber cup, and cold spray. The custom-made pulse oximeter dental probe is an effective and objective method for pulp vitality assessment.

摘要

简介

评估牙髓活力的理想技术应该是非侵入性的、无痛的、客观的、可靠的和可重复的。为了实现这一目标,最常规的测试是敏感性测试。然而,这些测试的一个主要缺点是,它们通过测量神经反应来间接指示牙髓活力。脉搏血氧仪是一种广泛应用于医学领域的成熟的氧饱和度监测技术。然而,其作为牙髓活力测试的效果仍需评估。本研究旨在设计和制造一种定制的脉搏血氧仪牙探头,并评估其与电动牙髓测试器、冷喷和橡胶杯在牙髓活力测试中的效果。

方法

选择 24 颗需要根管治疗的下颌前磨牙。患者没有系统性疾病,不服用药物,也没有明显的牙髓坏死迹象。这些牙齿分别用 4 种方法进行牙髓测试,包括脉搏血氧仪、电动测试、冷喷和橡胶杯。在这些牙齿的根管治疗完成后,显示了牙髓的实际状况,用卡帕检验分析结果,以显示这些测试的效果。

结果

将电、冷、热和脉搏血氧仪测试与金标准进行比较时,卡帕一致性系数分别为 18%、18%、14%和 91%。脉搏血氧仪、橡胶杯、电动测试和冷喷的灵敏度分别为 0.93、0.60、0.60 和 0.53。这些测试的特异性分别为 1.00、0.55、0.22 和 0.66。

结论

使用脉搏血氧仪进行牙髓测试比电动测试、橡胶杯和冷喷更可靠。定制的脉搏血氧仪牙探头是一种评估牙髓活力的有效和客观的方法。