Department of Conservative Dentistrty and Endodontics, Kalinga Institute of Dental Sciences, KIIT University, Bhubaneswar 751024, India.
Department of Dentistry, Faculty of Dental Sciences, University of Aldent, 1007 Tirana, Albania.
Int J Environ Res Public Health. 2022 Aug 4;19(15):9599. doi: 10.3390/ijerph19159599.
The current systematic review and meta-analysis was carried out to compare the diagnostic accuracy of pulp vitality and pulp sensibility tests in assessing pulpal health. PubMed/MEDLINE, Cochrane Central Register of Controlled Trials, Web of Science, Google Scholar and Open Grey databases were searched and after assessing eligibility criteria the data were extracted. True-positive, false-positive, true-negative, false-negative, sensitivity and specificity values were extracted or calculated if not presented. Quality of studies was evaluated based on the QUADAS 2 tool. Meta-analysis was performed in MetaDTA (v2.0; Shinyapps, RStudio PBC, Boston, MA, USA) and Review Manager 5.3 (RevMan web; The Cochrane Collaboration, London, UK). Ten articles were included for qualitative synthesis and five for meta-analysis. The pooled diagnostic odds ratio for pulse oximeter (PO), electric pulp tester (EPT), cold test (CT) and heat test (HT) was 628.5, 10.75, 17.24 and 3.47, respectively. Pairwise comparison demonstrated a higher pooled mean sensitivity and specificity with PO compared with EPT. Comparison between PO and CT and between PO and HT also demonstrated a higher pooled mean sensitivity and specificity for PO. Summary points on receiver operating characteristic curves confirmed the ability of PO to correctly screen negatives in presenting patients as compared to EPT, CT and HT but no study was rated as good on quality assessment. PO can be considered as the most accurate diagnostic method as compared to EPT, CT and HT. This review provides information about the reliability and diagnostic accuracy of using pulp vitality and sensibility tests for assessing pulp status.
本系统评价和荟萃分析旨在比较牙髓活力和牙髓感觉测试在评估牙髓健康方面的诊断准确性。检索了 PubMed/MEDLINE、Cochrane 对照试验中心注册库、Web of Science、Google Scholar 和 Open Grey 数据库,评估合格标准后提取数据。如果未呈现,则提取或计算真阳性、假阳性、真阴性、假阴性、敏感性和特异性值。根据 QUADAS 2 工具评估研究质量。在 MetaDTA (v2.0; Shinyapps, RStudio PBC, Boston, MA, USA) 和 Review Manager 5.3 (RevMan web; The Cochrane Collaboration, London, UK) 中进行荟萃分析。有 10 篇文章用于定性综合分析,5 篇用于荟萃分析。脉搏血氧仪 (PO)、电牙髓测试仪 (EPT)、冷测试 (CT) 和热测试 (HT) 的汇总诊断比值比分别为 628.5、10.75、17.24 和 3.47。两两比较显示,PO 的汇总平均敏感性和特异性均高于 EPT。PO 与 CT 之间以及 PO 与 HT 之间的比较也表明,PO 的汇总平均敏感性和特异性更高。受试者工作特征曲线的综合要点证实,与 EPT、CT 和 HT 相比,PO 能够正确筛选出呈阴性表现的患者,但是没有一项研究在质量评估中被评为良好。与 EPT、CT 和 HT 相比,PO 可以被认为是最准确的诊断方法。本综述提供了关于使用牙髓活力和感觉测试评估牙髓状态的可靠性和诊断准确性的信息。