Liu Yongtao, Ai Xiaohui, Li Le, Li Jincheng, Yang Hong
Yangtze River Fisheries Research Institute, Chinese Academy of Fishery Sciences, Wuhan, People's Republic of China.
Key Laboratory of Control of Quality and Safety for Aquatic Products, Ministry of Agriculture, Beijing, People's Republic of China.
Biomed Chromatogr. 2018 May;32(5):e4163. doi: 10.1002/bmc.4163. Epub 2018 Jan 10.
An accurate, rapid and effective method was established for determination of eugenol in plasma, muscle, skin, liver, kidney and gill of fish using gas chromatography-ion trap tandem mass spectrometry. Samples of muscle, skin, liver, kidney and gill were prepared using the modified QuEChERS (quick, easy, cheap, effective, rugged and safe) procedure, and a plasma sample was prepared by a liquid-liquid extraction procedure. Eugenol was monitored in <7 min using an electron-ionization source in MS/MS mode and quantified by an internal standard of eugenol-d . The limit of detection was 5.0 μg/kg, and the limit of quantification was 10.0 μg/kg. The calibration curve was linear in the range of 5-1000 μg/L (R = 0.9996). Intra- and inter-day precisions of eugenol expressed as relative standard deviation were within 9.74%, and the accuracy exhibited a relative error ranging from -2.20 to 8.89%. The developed method was successfully used to study the elimination regularity of eugenol in mandarin fish.
建立了一种准确、快速且有效的方法,采用气相色谱-离子阱串联质谱法测定鱼类血浆、肌肉、皮肤、肝脏、肾脏和鳃中丁香酚的含量。肌肉、皮肤、肝脏、肾脏和鳃的样品采用改良的QuEChERS(快速、简便、廉价、有效、耐用且安全)方法制备,血浆样品采用液-液萃取法制备。丁香酚在MS/MS模式下使用电子电离源在<7分钟内进行监测,并通过丁香酚-d内标进行定量。检测限为5.0μg/kg,定量限为10.0μg/kg。校准曲线在5-1000μg/L范围内呈线性(R = 0.9996)。以相对标准偏差表示的丁香酚日内和日间精密度在9.74%以内,准确度的相对误差范围为-2.20至8.89%。所建立的方法成功用于研究鳜鱼中丁香酚的消除规律。