Sepulveda Caviedes M F, Forbes B S, Pfau T
Department of Clinical Science and Services and Structure and Motion Lab, The Royal Veterinary College, Hatfield, Hertfordshire, UK.
Singapore Turf Club, Singapore, Singapore.
Equine Vet J. 2018 Jul;50(4):513-518. doi: 10.1111/evj.12802. Epub 2018 Jan 22.
With the view of implementing gait symmetry measurements in Thoroughbreds in training for early detection of injuries, repeatability of inertial measurement unit (IMU) gait parameters needs to be established.
To assess the variation of head and pelvis movement symmetry in Thoroughbreds in training.
Repeated observations in horses in race training.
Daily and weekly repeat gait assessments were conducted in 14 Thoroughbreds equipped with IMUs on poll, sacrum and right (RTC) and left (LTC) tuber coxae. Gait was assessed in trot, in-hand, on a level concrete surface. Difference between vertical displacement minima and maxima and range of motion (ROM) were obtained. Ranges containing 50% (median), 75, 90 and 95% of absolute daily and weekly differences were calculated and intraclass correlation coefficients (ICC) calculated for daily and weekly repeats.
Median absolute daily differences ranged from 4 to 7 mm and median weekly differences from 4 to 8 mm. 90% of daily differences were between 9 and 16 mm and 90% of weekly differences between 11 and 19 mm. ICC values were found on average across sensors and gait parameters as 0.73 (ranging from 0.40 to 0.92 across parameters) for daily repeats and as 0.65 (0.27 to 0.91) for weekly repeats.
Horses were of varying training and movement asymmetry levels, and no veterinary lameness examination was conducted.
Daily and weekly repeat gait assessments in this group of Thoroughbreds in training show lower ICC values than previously reported from within-day repeats in horses during lameness examinations. We recommend conducting repeatability studies for specific groups of horses when planning long-term studies aiming at identifying horses at risk of injury.
为了在训练中的纯种马身上实施步态对称性测量以早期发现损伤,需要确定惯性测量单元(IMU)步态参数的可重复性。
评估训练中纯种马头部和骨盆运动对称性的变化。
对参加赛马训练的马匹进行重复观察。
对14匹在枕部、骶骨以及右(RTC)、左(LTC)髋结节处配备IMU的纯种马进行每日和每周的重复步态评估。在水平混凝土表面以慢步进行牵遛步态评估。获取垂直位移最小值与最大值之间的差值以及运动范围(ROM)。计算包含每日和每周绝对差值的50%(中位数)、75%、90%和95%的范围,并计算每日和每周重复测量的组内相关系数(ICC)。
每日绝对差值中位数范围为4至7毫米,每周绝对差值中位数范围为4至8毫米。90%的每日差值在9至16毫米之间,90%的每周差值在11至19毫米之间。跨传感器和步态参数的ICC值,每日重复测量平均为0.73(各参数范围为0.40至0.92),每周重复测量平均为0.65(0.27至0.91)。
马匹的训练水平和运动不对称程度各不相同,且未进行兽医跛行检查。
这组训练中的纯种马每日和每周的重复步态评估显示,其ICC值低于先前在马匹跛行检查中日内重复测量所报告的值。我们建议在计划旨在识别有受伤风险马匹的长期研究时,针对特定组别的马匹进行可重复性研究。