Suppr超能文献

基于患者预后和步态参数的内侧旋转和髁型膝关节设计的功能比较。

A functional comparison of medial pivot and condylar knee designs based on patient outcomes and parameters of gait.

作者信息

Benjamin B, Pietrzak J R T, Tahmassebi J, Haddad F S

机构信息

University College London Hospitals, 235 Euston Road, NW1 2BU, London, UK.

University College London Hospitals, 235 Euston Road, London, NW1 2BU, UK and NIHR University College London Hospitals Biomedical Research Centre, UK.

出版信息

Bone Joint J. 2018 Jan;100-B(1 Supple A):76-82. doi: 10.1302/0301-620X.100B1.BJJ-2017-0605.R1.

Abstract

AIMS

The outcome of total knee arthroplasty (TKA) is not always satisfactory. The purpose of this study was to identify satisfaction and biomechanical features characterising the gait of patients who had undergone TKA with either an anatomical single radius design or a medial pivot design. We hypothesised that the latter would provide superior function.

PATIENTS AND METHODS

This is a study of a subset of patients recruited into a prospective randomised study of a single radius design a medial pivot design, with a minimum follow-up of one year. Outcome measurements included clinical scores (Knee Society Score (KSS) and Oxford Knee Score (OKS)) and gait analysis using an instrumented treadmill.

RESULTS

There was no statistically significant difference between the two groups for both the KSS and OKS. There was also no statistical significance in cadence, walking speed, stride length and stance time, peak stride, mid support and push-off forces.

CONCLUSION

This study corroborates a previous study by the same authors that showed equally good results in clinical outcome and gait between the conventional single radius and medial pivot designs under stringent testing conditions. Cite this article: 2018;(1 Supple A)100-B:76-82.

摘要

目的

全膝关节置换术(TKA)的结果并非总是令人满意。本研究的目的是确定接受解剖单半径设计或内侧旋转平台设计的TKA患者步态的满意度和生物力学特征。我们假设后者将提供更好的功能。

患者与方法

这是一项对纳入单半径设计与内侧旋转平台设计前瞻性随机研究的部分患者的研究,最短随访一年。结果测量包括临床评分(膝关节协会评分(KSS)和牛津膝关节评分(OKS))以及使用仪器化跑步机进行步态分析。

结果

两组在KSS和OKS方面均无统计学显著差异。在步频、步行速度、步幅长度和站立时间、最大步幅、支撑中期和蹬离力方面也无统计学意义。

结论

本研究证实了同一作者之前的一项研究,即在严格测试条件下,传统单半径设计和内侧旋转平台设计在临床结果和步态方面均有同样良好的效果。引用本文:2018;(1增刊A)100 - B:76 - 82。