Breast Cancer Unit, Department of Diagnostic Radiology, Reina Sofia University Hospital, Avenue Menéndez Pidal s/n, 14004, Córdoba, Spain.
Eur Radiol. 2018 Jun;28(6):2484-2491. doi: 10.1007/s00330-017-5219-8. Epub 2018 Jan 2.
To evaluate tomosynthesis compared with 2D-mammography in cancer detection and recalls in a screening-programme, and assess performing synthesized instead of 2D, and compare double reading of 2D with single reading of tomosynthesis.
Women (age 50-69 years) participating in the screening-programme were included. 2D-mammography and tomosynthesis were performed. There were four reading models: 2D-mammography (first); 2D-mammography (second); tomosynthesis + synthesized (third); tomosynthesis + synthesized + 2D (fourth reading). Paired double reading of 2D (first+second) and tomosynthesis (third+fourth) were analysed.
In 16,067 participants, there were 98 cancers and 1,196 recalls. Comparing double reading of 2D with single reading of tomosynthesis, there was an increase of 12.6 % in cancer detection with the third reading (p= 0.043) and 6.9 % with the fourth reading (p=0.210), and a decrease in recalls of 40.5 % (p<0.001) and 44.4 % (p<0.001), respectively. With double reading of both techniques, there was an increase in cancer detection of 17.4 % (p = 0.004) and a decrease in recalls of 12.5 % (p = 0.001) with tomosynthesis.
Single reading of tomosynthesis plus synthesized increased cancer detection and decreased recalls compared with double reading 2D. 2D did not improve results when added to tomosynthesis.
• Tomosynthesis increases cancer detection and decreases recall rates versus 2D mammography. • Synthesized-mammography avoids performing 2D, showing higher cancer detection. • Single reading of tomosynthesis + synthesized is feasible as a new practice.
在筛查项目中评估断层合成摄影与二维乳腺 X 线摄影在癌症检出和召回方面的差异,并评估合成断层合成摄影替代二维乳腺 X 线摄影的效果,比较二维乳腺 X 线摄影与断层合成摄影单次阅读与双次阅读的效果。
纳入参加筛查项目的年龄在 50-69 岁的女性。进行二维乳腺 X 线摄影和断层合成摄影。有四种阅读模式:二维乳腺 X 线摄影(首次);二维乳腺 X 线摄影(再次);断层合成摄影+合成断层(第三次);断层合成摄影+合成断层+二维(第四次阅读)。分析了二维乳腺 X 线摄影(首次+再次)和断层合成摄影(第三次+第四次)的双次阅读。
在 16067 名参与者中,有 98 例癌症和 1196 例召回。与断层合成摄影单次阅读相比,第三次阅读时癌症检出率增加了 12.6%(p=0.043),第四次阅读时增加了 6.9%(p=0.210),召回率分别降低了 40.5%(p<0.001)和 44.4%(p<0.001)。两种技术的双次阅读时,断层合成摄影的癌症检出率增加了 17.4%(p=0.004),召回率降低了 12.5%(p=0.001)。
与双次二维阅读相比,断层合成摄影单次阅读增加了癌症检出率,降低了召回率。添加断层合成摄影并不能提高二维乳腺 X 线摄影的结果。
断层合成摄影与二维乳腺 X 线摄影相比,提高了癌症检出率,降低了召回率。
合成断层合成摄影避免了二维乳腺 X 线摄影的操作,提高了癌症检出率。
断层合成摄影+合成断层的单次阅读是一种可行的新方法。