1 Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, IL, USA.
Cartilage. 2019 Apr;10(2):222-228. doi: 10.1177/1947603517752058. Epub 2018 Jan 17.
To determine biomechanical effects of knee cartilage defect perimeter morphology based on cartilage strain and opposing subchondral bone contact.
Articular cartilage defects were created in 5 bovine femoral condyles: group 1, 45° inner bevel with 8-mm rim; group 2, vertical with 8-mm rim; and group 3, 45° outer bevel with 8-mm base. Samples were placed into a custom-machined micro-computed tomography tube and subjected to 800 N of axial loading. DICOM data were used to calculate cartilage thickness 4 and 6 mm from the center, distance between tibial cartilage surface and femoral subchondral bone, and contact width between tibial cartilage and subchondral bone. Strain 4 mm from the center and both absolute and change in distance (mm) to subchondral bone were compared between groups 1 and 2 using paired t tests. Strain at 6 mm and distance changed, loaded distance, and contact width (mm) were compared between groups using the Friedman test with post hoc analysis using Wilcoxon signed rank test.
No significant differences in rim strain were noted between groups 1 and 2 at 4 mm ( P = 0.10) and between groups 1, 2, and 3 at 6 mm ( P = 0.247) from the defect center. The loaded distance was significantly different between groups 1 and 3 ( P = 0.013). No significant change in distance to the subchondral bone was found between groups ( P = 0.156). The difference in subchondral bone contact area approached but did not reach significance ( P = 0.074).
When debriding focal articular cartilage defects, establishment of an inner bevel decreases tissue deformation and contact with opposing subchondral bone.
基于软骨应变和对向软骨下骨接触,确定膝关节软骨缺损周界形态的生物力学效应。
在 5 个牛股骨髁上创建关节软骨缺损:第 1 组,内斜 45°,边缘 8mm;第 2 组,垂直,边缘 8mm;第 3 组,外斜 45°,基底 8mm。样本放入定制的微 CT 管中,施加 800N 的轴向载荷。使用 DICOM 数据计算距中心 4 和 6mm 处的软骨厚度、胫骨软骨表面与股骨软骨下骨之间的距离以及胫骨软骨与软骨下骨之间的接触宽度。使用配对 t 检验比较第 1 组和第 2 组中心 4mm 处的应变以及距软骨下骨的绝对和变化距离(mm)。使用 Friedman 检验比较第 2 组和第 3 组的应变和距离变化、加载距离和接触宽度(mm),并使用 Wilcoxon 符号秩检验进行事后分析。
从缺损中心 4mm 处,第 1 组和第 2 组的边缘应变无显著差异(P=0.10),第 1 组、第 2 组和第 3 组的 6mm 处的应变无显著差异(P=0.247)。第 1 组和第 3 组的加载距离有显著差异(P=0.013)。各组之间距软骨下骨的距离无明显变化(P=0.156)。软骨下骨接触面积的差异接近但未达到显著性(P=0.074)。
在清创局灶性关节软骨缺损时,建立内斜面可减少组织变形和与对向软骨下骨的接触。