Askarizadeh Farshad, Sedaghat Mohamad-Reza, Ostadi-Moghaddam Hadi, Narooie-Noori Foroozan, Rakhshandadi Tahereh, Rajabi Sattar
Refractive Errors Research Center, Mashhad University of Medical Sciences, Mashhad, Iran.
Department of Optometry, School of Paramedical Science, Mashhad University of Medical Sciences, Mashhad, Iran.
Med Hypothesis Discov Innov Ophthalmol. 2017 Summer;6(2):49-55.
The aim of this study was to analyze and compare corneal biomechanics in patients with bilateral keratoconus (KCN) with unilateral Vogt's striae. In this prospective contralateral study, visual acuity, refraction, and corneal biomechanical parameters were evaluated in patients with bilateral KCN with unilateral Vogt's striae using the Ocular Response Analyzer (ORA) (Reichert Inc., Buffalo, NY) and Corvis ST (Oculus Optikgeräte GmbH, Wetzlar, Germany). All patients underwent a comprehensive ophthalmic examination, including uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), refraction (calculated by vectorial analysis), slit-lamp biomicroscopy, and Scheimpflug-based tomography. The patients enrolled in this study had a reliable diagnosis of bilateral clinical KCN with unilateral Vogt's striae based on slit-lamp signs as well as corneal topographic/tomographic maps. Fifty patients aged 18 to 40 years were included in this study. There was a significant difference in all clinical (distance visual acuity and refraction) and corneal biomechanical parameters between KCN eyes with and without unilateral Vogt's striae (all P < 0.05). However, there were no significant differences in peak distance (P = 0.291), corneal compensated intraocular pressure (IOPCC) (P = 0.08), and J45 (P = 0.131) between the two groups. Most corneal biomechanical parameters, except for peak distance, IOPCC, and J45, showed a significant difference between KCN eyes with and without unilateral Vogt's striae. Vogt's striae may cause corneal biomechanical deterioration. This information could be used in clinical practice.
本研究的目的是分析和比较双侧圆锥角膜(KCN)伴单侧Vogt条纹患者的角膜生物力学。在这项前瞻性对侧研究中,使用眼反应分析仪(ORA)(Reichert公司,纽约州布法罗)和Corvis ST(德国韦茨拉尔Oculus Optikgeräte GmbH)对双侧KCN伴单侧Vogt条纹的患者进行视力、验光和角膜生物力学参数评估。所有患者均接受了全面的眼科检查,包括未矫正远视力(UDVA)、矫正远视力(CDVA)、验光(通过矢量分析计算)、裂隙灯生物显微镜检查和基于Scheimpflug的断层扫描。根据裂隙灯体征以及角膜地形图/断层扫描图,本研究纳入的患者被可靠诊断为双侧临床KCN伴单侧Vogt条纹。本研究纳入了50名年龄在18至40岁之间的患者。有单侧Vogt条纹和无单侧Vogt条纹的KCN眼在所有临床(远视力和验光)和角膜生物力学参数上均存在显著差异(所有P<0.05)。然而,两组之间的峰值距离(P = 0.291)、角膜补偿眼压(IOPCC)(P = 0.08)和J45(P = 0.131)无显著差异。除峰值距离、IOPCC和J45外,大多数角膜生物力学参数在有单侧Vogt条纹和无单侧Vogt条纹的KCN眼之间存在显著差异。Vogt条纹可能导致角膜生物力学恶化。该信息可用于临床实践。