Suppr超能文献

无柄解剖型肩关节置换术的长期生存率

Long-term survivorship of stemless anatomical shoulder replacement.

作者信息

Beck Sascha, Beck Verena, Wegner Alexander, Dudda Marcel, Patsalis Theodor, Jäger Marcus

机构信息

Department of Orthopaedics and Trauma Surgery, University Hospital Essen, University of Duisburg-Essen, Hufelandstrasse 55, 45147, Essen, Germany.

Department of Shoulder, Elbow, Hand and Foot Surgery, St. Josef Hospital, Bergstrasse 6-12, 42105, Wuppertal, Germany.

出版信息

Int Orthop. 2018 Jun;42(6):1327-1330. doi: 10.1007/s00264-018-3779-0. Epub 2018 Jan 24.

Abstract

PURPOSE

Like in many other joints, current shoulder replacement designs aim at bone preservation. According to the literature available, stemless total shoulder arthroplasty (TSA) compares favourably with stemmed designs in terms of function and survivorship of the implant. However, long-term results of stemless shoulder arthroplasty are still missing. Therefore, the aim of the present study was to evaluate long-term results of stemless anatomical TSA.

METHODS

Between 2006 and 2009, 51 shoulders in 46 patients were resurfaced using the Biomet Total Evolutive Shoulder System (TESS). Thirty-one shoulders in 26 patients who were aged 66.7 ± 10.0 (range 34-82) years were available for review at a mean follow-up of 94.7 ± 11.3 (76-124) months.

RESULTS

The implant survival rate was 93.5% at eight years. The overall revision rate of the TESS implant was 9.7%. Radiolucent lines were found on the glenoid side of the TESS arthroplasty in 90.9% of the cases. All stemless humeral corolla implants showed solid fixation at follow-up. Clinical scores significantly improved at long-term follow-up (VAS from 8.1 ± 0.9 to 1.0 ± 1.2, p < 0.001; Quick-DASH from 67.9 ± 13.5 to 18.7 ± 16.5, p < 0.001 and Constant score from 14.7 ± 6.1 to 68.8 ± 13.2, p < 0.001).

CONCLUSIONS

Stemless TSA has stood the test of time at eight years in terms of clinical scores, radiographic loosening, complication rates and implant survivorship.

摘要

目的

与许多其他关节一样,当前的肩关节置换设计旨在保留骨质。根据现有文献,无柄全肩关节置换术(TSA)在功能和植入物存活率方面与有柄设计相比具有优势。然而,无柄肩关节置换术的长期结果仍然缺乏。因此,本研究的目的是评估无柄解剖型TSA的长期结果。

方法

2006年至2009年期间,使用Biomet全进化肩关节系统(TESS)对46例患者的51个肩关节进行了表面置换。对26例年龄为66.7±10.0(范围34 - 82)岁患者的31个肩关节进行了回顾性研究,平均随访时间为94.7±11.3(76 - 124)个月。

结果

八年时植入物存活率为93.5%。TESS植入物的总体翻修率为9.7%。在90.9%的病例中,TESS关节置换术的关节盂侧发现了透光线。所有无柄肱骨头假体在随访时均显示固定牢固。长期随访时临床评分显著改善(视觉模拟评分法(VAS)从8.1±0.9降至1.0±1.2,p<0.001;快速残疾评定量表(Quick - DASH)从67.9±13.5降至18.7±16.5,p<0.001;常数评分从14.7±6.1升至68.8±13.2,p<0.001)。

结论

就临床评分、影像学松动、并发症发生率和植入物存活率而言,无柄TSA在八年时经受住了时间的考验。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验