Capa N, Celebi C, Casur A, Tuncel I, Usumez A
Department of Prosthodontics, Faculty of Dentistry, Yeditepe University, Istanbul, Turkey.
Department of Prosthodontics, Faculty of Dentistry, Bezmialem Vakif University, Istanbul, Turkey.
Niger J Clin Pract. 2017 Dec;20(12):1517-1521. doi: 10.4103/njcp.njcp_160_17.
The purpose of this study was to evaluate the effect of the different color of resin cements and zirconia cores on the translucency parameter (TP) of the restoration that simulates the implant-supported fixed prosthesis using titanium base on the bottom.
Zirconia core plates (Zr-Zahn) were prepared in A2 shades (n = 11). Resin cement plates (3M ESPE) were prepared in A2, A1, translucent (TR) shades (n = 11). The initial color measurements and were measured on zirconia core plates, and resin cements plates using a spectrophotometer. Then, the resin cement plates were placed below the zirconia core plates, and the second measurements were done. The final measurements were done after placing the titanium discs in the bottom. The data were analyzed with two-way analysis of variance and Tukey honestly significant differences tests (α = 0.05).
The highest TP values were recorded for A1-colored resin specimens and the lowest for zirconia core plates in the first measurement (P < 0.05). The addition of zirconia core decreased the TP values in all tested resin cement groups (P < 0.05). The highest TP value was recorded for A1-colored resin cement with zirconia core plates and the lowest for A2 and TR with zirconia core plates after second measurements (P < 0.05). The addition of titanium decreased the TP of the zirconia core plate and resin cement combination (P < 0.05).
The addition of a zirconia core under the resin cement dramatically reduced the TP values, and the presence of a titanium layer decreased the TP value and caused a darker appearance.
本研究旨在评估不同颜色的树脂水门汀和氧化锆核对于修复体透光参数(TP)的影响,该修复体模拟底部采用钛基的种植体支持固定义齿。
制备A2色的氧化锆核板(Zr-Zahn,n = 11)。制备A2、A1、半透明(TR)色的树脂水门汀板(3M ESPE,n = 11)。使用分光光度计对氧化锆核板和树脂水门汀板进行初始颜色测量。然后,将树脂水门汀板置于氧化锆核板下方进行第二次测量。在底部放置钛盘后进行最终测量。数据采用双向方差分析和Tukey真实显著性差异检验进行分析(α = 0.05)。
在第一次测量中,A1色树脂样本的TP值最高,氧化锆核板的TP值最低(P < 0.05)。添加氧化锆核降低了所有测试树脂水门汀组的TP值(P < 0.05)。第二次测量后,A1色树脂水门汀与氧化锆核板组合的TP值最高,A2和TR色与氧化锆核板组合的TP值最低(P < 0.05)。添加钛降低了氧化锆核板与树脂水门汀组合的TP值(P < 0.05)。
在树脂水门汀下方添加氧化锆核显著降低了TP值,钛层的存在降低了TP值并导致外观更暗。