Suppr超能文献

提高血压测量准确性:验证血压测量设备的欧洲高血压学会国际协议(ESH-IP)的影响及未来展望。

Improving the accuracy of blood pressure measurement: the influence of the European Society of Hypertension International Protocol (ESH-IP) for the validation of blood pressure measuring devices and future perspectives.

机构信息

Hypertension Center STRIDE-7, National and Kapodistrian University of Athens, School of Medicine, Third Department of Medicine, Sotiria Hospital, Athens, Greece.

Foundation, Medical Research Institutes, Paris, France.

出版信息

J Hypertens. 2018 Mar;36(3):479-487. doi: 10.1097/HJH.0000000000001635.

Abstract

INTRODUCTION

The European Society of Hypertension (ESH) International Protocol (ESH-IP) for the validation of blood pressure (BP) measuring devices was published in 2002, with the main objective of simplifying the validation procedures, so that more BP monitors would be subjected to independent validation. This article provides an overview of the international impact of the ESH-IP and of the lessons learned from its use, to be able to justify further developments in validation protocols.

METHODS

A review of published (PubMed) validation studies from 2002 to 2017 was performed.

RESULTS

One hundred and seventy-seven validation studies using the ESH-IP, 59 using the British Hypertension Society protocol, 46 using the Association for the Advancement of Medical Instrumentation (AAMI) standard and 23 using the International Organization for Standardization (ISO) standard were identified. Lists of validated office-clinic, home and ambulatory BP monitors are provided. Of the ESH-IP studies, 93% tested oscillometric devices, 80% upper arm, 71% home, 25% office and 7% ambulatory monitors (some had more than one function).

CONCLUSION

The original goal of the ESH-IP has been fulfilled in that in the last decade the number of published validation studies has more than doubled. It is now recognized that the provision of accurate devices would be best served by having a universal protocol. An international initiative has been put in place by AAMI, ESH and ISO experts aiming to reach consensus for a universal validation protocol to be accepted worldwide, which will allow a more thorough evaluation of the accuracy and performance of future BP monitors.

摘要

简介

欧洲高血压学会(ESH)国际协议(ESH-IP)于 2002 年发布,用于验证血压(BP)测量设备,其主要目标是简化验证程序,从而使更多的血压监护仪接受独立验证。本文概述了 ESH-IP 的国际影响以及从其使用中获得的经验教训,以便为验证协议的进一步发展提供依据。

方法

对 2002 年至 2017 年发表的(PubMed)验证研究进行了回顾。

结果

共发现 177 项使用 ESH-IP 的验证研究、59 项使用英国高血压学会方案的研究、46 项使用医疗器械促进协会(AAMI)标准的研究和 23 项使用国际标准化组织(ISO)标准的研究。提供了经过验证的诊室、家庭和动态血压监护仪列表。ESH-IP 研究中,93%测试了示波法设备,80%为上臂设备,71%为家庭设备,25%为诊室设备,7%为动态设备(有些设备具有多种功能)。

结论

ESH-IP 的原始目标已经实现,即在过去十年中,发表的验证研究数量增加了一倍以上。现在人们认识到,提供准确的设备最好采用通用协议。AAMI、ESH 和 ISO 专家已采取国际行动,旨在就通用验证协议达成共识,以便在全球范围内得到接受,这将允许更彻底地评估未来血压监护仪的准确性和性能。