Suppr超能文献

采用快速千伏切换技术的低辐射和低对比剂剂量双能谱CT对头颈部进行减影CT血管造影。

Subtraction CT angiography in head and neck with low radiation and contrast dose dual-energy spectral CT using rapid kV-switching technique.

作者信息

Ma Guangming, Yu Yong, Duan Haifeng, Dou Yuequn, Jia Yongjun, Zhang Xirong, Yang Chuangbo, Chen Xiaoxia, Han Dong, Guo Changyi, He Taiping

机构信息

1 Department of Diagnostic Radiology, Affiliated Hospital of Shaanxi University of Chinese Medicine , Xianyang , China.

2 Department of Diagnostic Radiology, The Second Affiliated Hospital of the Shannxi University of Traditional Chinese Medicine , Xianyang , China.

出版信息

Br J Radiol. 2018 Jun;91(1086):20170631. doi: 10.1259/bjr.20170631. Epub 2018 Mar 7.

Abstract

OBJECTIVE

To investigate the application of low radiation and contrast dose spectral CT angiology using rapid kV-switching technique in the head and neck with subtraction method for bone removal.

METHODS

This prospective study was approved by the local ethics committee. 64 cases for head and neck CT angiology were randomly divided into Groups A (n = 32) and B (n = 32). Group A underwent unenhanced CT with 100 kVp, 200 mA and contrast-enhanced CT with spectral CT mode with body mass index-dependent low dose protocols. Group B used conventional helical scanning with 120 kVp, auto mA for noise index of 12 HU (Hounsfield unit) for both the unenhanced and contrast-enhanced CT. Subtraction images were formed by subtracting the unenhanced images from enhanced images (with the 65 keV-enhanced spectral CT image in Group A). CT numbers and their standard deviations in aortic arch, carotid arteries, middle cerebral artery and air were measured in the subtraction images. The signal-to-noise ratio and contrast-to-noise ratio for the common and internal carotid arteries and middle cerebral artery were calculated. Image quality in terms of bone removal effect was evaluated by two experienced radiologists independently and blindly using a 4-point system. Radiation dose and total iodine load were recorded. Measurements were statistically compared between the two groups.

RESULTS

The two groups had same demographic results. There was no difference in the CT number, signal-to-noise and contrast-to-noise ratio values for carotid arteries and middle cerebral artery in the subtraction images between the two groups (p > 0.05). However, the bone removal effect score [median (min-max)] in Group A [4 (3-4)] was rated better than in Group B [3 (2-4)] (p < 0.001), with excellent agreement between the two observers (κ > 0.80). The radiation dose in Group A (average of 2.64 mSv) was 57% lower than the 6.18 mSv in Group B (p < 0.001). The total iodine intake in Group A was 13.5g, 36% lower than the 21g in Group B.

CONCLUSION

Spectral CT imaging with rapid kV-switching in the subtraction angiography in head and neck provides better bone removal with significantly reduced radiation and contrast dose compared with conventional subtraction method. Advances in knowledge: This novel method provides better bone removal with significant radiation and contrast dose reduction compared with the conventional subtraction CT, and maybe used clinically to protect the thyroid gland and ocular lenses from unnecessary high radiation.

摘要

目的

探讨采用快速千伏切换技术的低辐射和低对比剂剂量的光谱CT血管成像技术在头颈部应用减影法去除骨组织的效果。

方法

本前瞻性研究经当地伦理委员会批准。64例头颈部CT血管成像患者随机分为A组(n = 32)和B组(n = 32)。A组采用100 kVp、200 mA进行平扫CT,并采用基于体重指数的低剂量方案以光谱CT模式进行增强CT扫描。B组在平扫和增强CT扫描时均采用120 kVp、自动毫安设置,使噪声指数为12 HU(亨氏单位)。通过从增强图像(A组为65 keV增强光谱CT图像)中减去平扫图像来生成减影图像。在减影图像中测量主动脉弓、颈动脉、大脑中动脉及空气的CT值及其标准差。计算颈总动脉、颈内动脉和大脑中动脉的信噪比和对比噪声比。由两名经验丰富的放射科医生独立且盲法地使用4分制系统评估减影图像在去除骨组织效果方面的图像质量。记录辐射剂量和总碘负荷。对两组测量结果进行统计学比较。

结果

两组患者的人口统计学结果相同。两组减影图像中颈动脉和大脑中动脉的CT值、信噪比和对比噪声比值均无差异(p > 0.05)。然而,A组的去除骨组织效果评分[中位数(最小值 - 最大值)]为[4(3 - 4)],优于B组的[3(2 - 4)](p < 0.001),两位观察者之间的一致性良好(κ > 0.80)。A组的辐射剂量(平均2.(此处原文有误,应为2.64)mSv)比B组的6.18 mSv低57%(p < 0.001)。A组的总碘摄入量为13.5 g,比B组的21 g低36%。

结论

与传统减影法相比,头颈部减影血管造影中采用快速千伏切换的光谱CT成像能更好地去除骨组织,同时显著降低辐射剂量和对比剂剂量。知识进展:与传统减影CT相比,这种新方法能更好地去除骨组织,且显著降低辐射剂量和对比剂剂量,可能在临床上用于保护甲状腺和晶状体免受不必要的高辐射。

相似文献

引用本文的文献

4

本文引用的文献

7
Vascular imaging of the head and neck.头颈部血管成像。
Semin Neurol. 2012 Sep;32(4):401-10. doi: 10.1055/s-0032-1331811. Epub 2013 Jan 29.

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验