Ohnishi Yasuo, Chang Angela, Utsunomiya Hajime, Suzuki Hitoshi, Nakamura Eiichiro, Sakai Akinori, Uchida Soshi
Department of Orthopaedic Surgery, Wakamatsu Hospital for the University of Occupational and Environmental Health, Kitakyushu, Japan.
Steadman Philippon Research Institute, Vail, Colorado, U.S.A.
Arthrosc Tech. 2017 Oct 23;6(5):e1927-e1931. doi: 10.1016/j.eats.2017.07.016. eCollection 2017 Oct.
Suture button-based femoral cortical suspension constructs of anterior cruciate ligament grafts can facilitate a fast and secure fixation. However, there are several case reports showing button malpositioning resulting from the inability to visualize the "flipped" button. Many current surgical techniques do not allow direct visualization of EndoButtons (Smith & Nephew, Andover, MA) in their final position, making it difficult to ensure that both buttons are fully flipped and that there is no soft-tissue interposition between the button and femur. We describe an arthroscopic technique for making femoral tunnels through the outside-in method that reduces the migration of the EndoButton through a lateral femoral portal. This technique may assist surgeons in understanding how to deal with and potentially avoid EndoButton migration during anterior cruciate ligament reconstruction.