Arthroscopic Technique to Reduce Suture Button Migration During Anterior Cruciate Ligament Reconstruction Procedure.

作者信息

Ohnishi Yasuo, Chang Angela, Utsunomiya Hajime, Suzuki Hitoshi, Nakamura Eiichiro, Sakai Akinori, Uchida Soshi

机构信息

Department of Orthopaedic Surgery, Wakamatsu Hospital for the University of Occupational and Environmental Health, Kitakyushu, Japan.

Steadman Philippon Research Institute, Vail, Colorado, U.S.A.

出版信息

Arthrosc Tech. 2017 Oct 23;6(5):e1927-e1931. doi: 10.1016/j.eats.2017.07.016. eCollection 2017 Oct.

Abstract

Suture button-based femoral cortical suspension constructs of anterior cruciate ligament grafts can facilitate a fast and secure fixation. However, there are several case reports showing button malpositioning resulting from the inability to visualize the "flipped" button. Many current surgical techniques do not allow direct visualization of EndoButtons (Smith & Nephew, Andover, MA) in their final position, making it difficult to ensure that both buttons are fully flipped and that there is no soft-tissue interposition between the button and femur. We describe an arthroscopic technique for making femoral tunnels through the outside-in method that reduces the migration of the EndoButton through a lateral femoral portal. This technique may assist surgeons in understanding how to deal with and potentially avoid EndoButton migration during anterior cruciate ligament reconstruction.

摘要

基于缝线纽扣的前交叉韧带移植物股骨皮质悬吊结构可实现快速、牢固的固定。然而,有几例病例报告显示,由于无法看到“翻转”的纽扣,纽扣出现了位置不当的情况。目前许多手术技术无法直接观察到EndoButtons(史赛克公司,马萨诸塞州安多弗)在其最终位置的情况,因此难以确保两个纽扣都完全翻转,且纽扣与股骨之间没有软组织夹入。我们描述了一种通过由外向内法制作股骨隧道的关节镜技术,该技术可减少EndoButton通过外侧股骨入路的移位。该技术可能有助于外科医生了解如何处理并可能避免在前交叉韧带重建过程中出现EndoButton移位的情况。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/73d5/5797844/78d3e89437c3/gr1.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验