Asano Yudai, Tada Akihiro, Shinya Takayoshi, Masaoka Yoshihisa, Iguchi Toshihiro, Sato Shuhei, Kanazawa Susumu
Department of Radiology, Okayama University Hospital, 2-5-1 Shikatacho, Kita-ku, Okayama-city, 700-8558, Okayama, Japan.
Department of Health Informatics, Kawasaki University of Medical Welfare, Okayama, Japan.
Jpn J Radiol. 2018 Apr;36(4):285-294. doi: 10.1007/s11604-018-0723-6. Epub 2018 Feb 10.
The quality of images acquired using single-energy metal artifact reduction (SEMAR) on helical lung computed tomography (CT) in patients with pulmonary arteriovenous malformation (PAVM) after coil embolization was retrospectively evaluated.
CT images were reconstructed with and without SEMAR. Twenty-seven lesions [20 patients (2 males, 18 females), mean age 61.2 ± 11.0 years; number of embolization coils, 9.8 ± 5.0] on contrast-enhanced CT and 18 lesions of non-enhanced lung CT concurrently performed were evaluated. Regions of interest were positioned around the coils and mean standard deviation value was compared as noise index. Two radiologists visually evaluated metallic coil artifacts using a four-point scale: 4 = minimal; 3 = mild; 2 = strong; 1 = extensive.
Noise index was significantly improved with SEMAR versus without SEMAR (median [interquartile range]; 194.4 [161.6-211.9] Hounsfield units [HU] vs. 243.9 [220.4-286.0] HU; p < 0.001). Visual score was significantly improved with SEMAR versus without SEMAR (Reader 1, 3 [3] vs.1 [1]; Reader 2, 3 [3] vs.1 [1]; p < 0.001). Significant differences were similarly demonstrated on lung CT (p < 0.001).
SEMAR provided clear chest CT images in patients who underwent PAVM coil embolization.
回顾性评估在接受弹簧圈栓塞治疗的肺动静脉畸形(PAVM)患者中,使用单能量金属伪影减少(SEMAR)技术进行螺旋肺计算机断层扫描(CT)所获得图像的质量。
分别在有和没有使用SEMAR的情况下重建CT图像。对27个病变[20例患者(2例男性,18例女性),平均年龄61.2±11.0岁;栓塞弹簧圈数量为9.8±5.0]的增强CT图像以及同时进行的18个非增强肺CT病变进行评估。在弹簧圈周围设置感兴趣区域,并比较平均标准差作为噪声指数。两名放射科医生使用四点量表对金属弹簧圈伪影进行视觉评估:4=最小;3=轻度;2=重度;1=广泛。
与未使用SEMAR相比,使用SEMAR时噪声指数显著改善(中位数[四分位间距];194.4[161.6-211.9]亨氏单位[HU]对243.9[220.4-286.0]HU;p<0.001)。与未使用SEMAR相比,使用SEMAR时视觉评分显著改善(读者1,3[3]对1[1];读者2,3[3]对1[1];p<0.001)。在肺CT上也同样显示出显著差异(p<0.001)。
SEMAR为接受PAVM弹簧圈栓塞治疗的患者提供了清晰的胸部CT图像。