Suppr超能文献

使用中性环糊精作为清扫剂增强毛细管电泳系统中的电导率检测信号。

Enhancement of the conductivity detection signal in capillary electrophoresis systems using neutral cyclodextrins as sweeping agents.

作者信息

Boublík Milan, Riesová Martina, Dubský Pavel, Gaš Bohuslav

机构信息

Faculty of Science, Department of Physical and Macromolecular Chemistry, Charles University in Prague, Prague, Czech Republic.

出版信息

Electrophoresis. 2018 Jun;39(11):1390-1398. doi: 10.1002/elps.201800027. Epub 2018 Mar 8.

Abstract

Conductivity detection is a universal detection technique often encountered in electrophoretic separation systems, especially in modern chip-electrophoresis based devices. On the other hand, it is sparsely combined with another contemporary trend of enhancing limits of detection by means of various preconcentration strategies. This can be attributed to the fact that a preconcentration experimental setup usually brings about disturbances in a conductivity baseline. Sweeping with a neutral sweeping agent seems a good candidate for overcoming this problem. A neutral sweeping agent does not hinder the conductivity detection while a charged analyte may preconcentrate on its boundary due to a decrease in its effective mobility. This study investigates such sweeping systems theoretically, by means of computer simulations, and experimentally. A formula is provided for the reliable estimation of the preconcentration factor. Additionally, it is demonstrated that the conductivity signal can significantly benefit from slowing down the analyte and thus the overall signal enhancement can easily overweight amplification caused solely by the sweeping process. The overall enhancement factor can be deduced a priori from the linearized theory of electrophoresis implemented in the PeakMaster freeware. Sweeping by neutral cyclodextrin is demonstrated on an amplification of a conductivity signal of flurbiprofen in a real drug sample. Finally, a possible formation of unexpected system peaks in systems with a neutral sweeping agent is revealed by the computer simulation and confirmed experimentally.

摘要

电导率检测是电泳分离系统中常用的一种通用检测技术,尤其在基于现代芯片电泳的设备中。另一方面,它很少与另一种通过各种预富集策略提高检测限的当代趋势相结合。这可能是由于预富集实验装置通常会导致电导率基线出现干扰。使用中性清扫剂进行清扫似乎是解决这个问题的一个不错选择。中性清扫剂不会妨碍电导率检测,而带电分析物可能会因其有效迁移率降低而在其边界处预富集。本研究通过计算机模拟从理论上以及通过实验对这种清扫系统进行了研究。提供了一个用于可靠估计预富集因子的公式。此外,还证明了电导率信号可以通过减慢分析物的速度而显著受益,因此整体信号增强很容易超过仅由清扫过程引起的放大。整体增强因子可以从PeakMaster免费软件中实现的线性化电泳理论先验推导出来。在实际药物样品中,通过中性环糊精清扫证明了氟比洛芬电导率信号的放大。最后,计算机模拟揭示并通过实验证实了在使用中性清扫剂的系统中可能会形成意外的系统峰。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验