Assessment of Screw Length of Proximal Humerus Internal Locking System (PHILOS) Plate for Proximal Humeral Fractures Using Three-Dimensional Computed Tomography Scan.

机构信息

Department of Orthopedic Trauma, East Hospital, Tongji University School of Medicine, Shanghai, China (mainland).

出版信息

Med Sci Monit. 2018 Feb 25;24:1158-1165. doi: 10.12659/msm.906355.

Abstract

BACKGROUND Screw perforation and varus collapse are common complications of treatment with a PHILOS (proximal humerus internal locking system) plate for proximal humerus fractures, which are associated with improper screw length selection and lack of medial column support. The purposes of this study were: (1) to measure the proper length of periarticular screws of the PHILOS plate in the humeral head, and (2) to determine what factors influence the screw length and implantation of the inferomedial support screw. MATERIAL AND METHODS Computed tomography (CT) images of the normal proximal humerus in 134 cases were retrospectively reviewed. The length of periarticular screws was measured using three-dimensional (3D) techniques. Intraobserver and interobserver reliability of measurement were evaluated using intraclass correlation coefficients (ICCs). Sex and body height influences on screw length and implantation of the inferomedial screw were analyzed. RESULTS All measurements had excellent agreement (ICC>0.75). The screw length and implantation rate of the inferomedial screw were greater in males than in females. Positive correlations were observed between body height and screw length and implantation of the inferomedial screw (all P<0.001). CONCLUSIONS The screws were longer and the implantation rate was higher for inferomedial screws in males than in females, and were positively correlated with body height. Our data can be used as a reference for surgeons to reduce the number of times screws are changed intraoperatively and to reduce operation duration and minimize use of intraoperative fluoroscopy for proximal humerus fractures treated with the PHILOS plate.

摘要

背景

使用 PHILOS(肱骨近端锁定系统)板治疗肱骨近端骨折时,螺钉穿孔和内翻塌陷是常见的并发症,这与螺钉长度选择不当和缺乏内侧柱支撑有关。本研究的目的是:(1)测量 PHILOS 钢板在肱骨头内关节周围螺钉的合适长度;(2)确定影响螺钉长度和植入下内侧支撑螺钉的因素。

材料和方法

回顾性分析 134 例正常肱骨近端的 CT 图像。使用三维(3D)技术测量关节周围螺钉的长度。采用组内相关系数(ICC)评估测量的观察者内和观察者间可靠性。分析性别和身高对螺钉长度和下内侧螺钉植入的影响。

结果

所有测量均具有良好的一致性(ICC>0.75)。男性的螺钉长度和下内侧螺钉的植入率大于女性。身高与螺钉长度和下内侧螺钉植入呈正相关(均 P<0.001)。

结论

男性的螺钉更长,下内侧螺钉的植入率更高,与身高呈正相关。我们的数据可作为外科医生的参考,以减少术中螺钉更换次数,缩短手术时间,并最大限度地减少术中透视次数,从而治疗使用 PHILOS 板治疗的肱骨近端骨折。