A comparison of four-sample slope-intercept and single-sample 51Cr-EDTA glomerular filtration rate measurements.

作者信息

Porter Charlotte A, Bradley Kevin M, McGowan Daniel R

机构信息

Radiation Physics and Protection.

Department of Radiology, Churchill Hospital, Oxford University Hospitals NHS Foundation Trust.

出版信息

Nucl Med Commun. 2018 May;39(5):465-468. doi: 10.1097/MNM.0000000000000815.

DOI:10.1097/MNM.0000000000000815
PMID:29505482
Abstract

The aim of this study was to verify, with a large dataset of 1394 Cr-EDTA glomerular filtration rate (GFR) studies, the equivalence of slope-intercept and single-sample GFR. Raw data from 1394 patient studies were used to calculate four-sample slope-intercept GFR in addition to four individual single-sample GFR values (blood samples taken at 90, 150, 210 and 270 min after injection). The percentage differences between the four-sample slope-intercept and each of the single-sample GFR values were calculated, to identify the optimum single-sample time point. Having identified the optimum time point, the percentage difference between the slope-intercept and optimal single-sample GFR was calculated across a range of GFR values to investigate whether there was a GFR value below which the two methodologies cannot be considered equivalent. It was found that the lowest percentage difference between slope-intercept and single-sample GFR was for the third blood sample, taken at 210 min after injection. The median percentage difference was 2.5% and only 6.9% of patient studies had a percentage difference greater than 10%. Above a GFR value of 30 ml/min/1.73 m, the median percentage difference between the slope-intercept and optimal single-sample GFR values was below 10%, and so it was concluded that, above this value, the two techniques are sufficiently equivalent. This study supports the recommendation of performing single-sample GFR measurements for GFRs greater than 30 ml/min/1.73 m.

摘要

相似文献

1
A comparison of four-sample slope-intercept and single-sample 51Cr-EDTA glomerular filtration rate measurements.
Nucl Med Commun. 2018 May;39(5):465-468. doi: 10.1097/MNM.0000000000000815.
2
Comparison between terminal slope rate constant and "slope/intercept" as measures of glomerular filtration rate using the single-compartment simplification.使用单室简化模型,比较终末斜率速率常数和“斜率/截距”作为肾小球滤过率的测量指标。
Eur J Nucl Med. 2001 Mar;28(3):320-6. doi: 10.1007/s002590000433.
3
99mTc DTPA vs. 51Cr EDTA for glomerular filtration rate measurement: is there a systematic difference?用于肾小球滤过率测量的99m锝二乙三胺五乙酸与51铬依地酸:是否存在系统差异?
Nucl Med Commun. 2019 Dec;40(12):1224-1229. doi: 10.1097/MNM.0000000000001101.
4
Correlation of various published radionuclide glomerular filtration rate estimation techniques and proposed paediatric normative data.
Nucl Med Commun. 2011 Nov;32(11):1088-94. doi: 10.1097/MNM.0b013e32834b458c.
5
Comparison between slope-intercept and slope-only techniques for measuring glomerular filtration rate: use of two independent markers and an independent arbiter.测量肾小球滤过率的截距斜率法与仅斜率法的比较:使用两种独立标志物和一个独立判定指标。
Nucl Med Commun. 2007 Sep;28(9):711-8. doi: 10.1097/MNM.0b013e3281ec51b5.
6
Accurate measurement of extracellular fluid volume from the slope/intercept technique after bolus injection of a filtration marker.经滤过标志物团注后斜率/截距技术测量细胞外液容量的准确性。
Physiol Meas. 2009 Dec;30(12):1371-9. doi: 10.1088/0967-3334/30/12/006. Epub 2009 Oct 28.
7
Using the slope-only technique and estimated glomerular filtration rate for checking the reliability of slope-intercept measurement of glomerular filtration rate.使用仅斜率技术和估计的肾小球滤过率来检验肾小球滤过率斜率-截距测量的可靠性。
Nucl Med Commun. 2008 Dec;29(12):1086-92. doi: 10.1097/MNM.0b013e328310b378.
8
Reference data for 51Cr-EDTA measurements of the glomerular filtration rate derived from live kidney donors.来自活体肾供体的51铬-乙二胺四乙酸肾小球滤过率测量的参考数据。
Nucl Med Commun. 2005 Jan;26(1):61-5. doi: 10.1097/00006231-200501000-00010.
9
Correction of the slope-intercept method for the measurement of glomerular filtration rate.肾小球滤过率测量中斜率截距法的校正
Nucl Med Commun. 2014 Dec;35(12):1277-83. doi: 10.1097/MNM.0000000000000192.
10
Glomerular Filtration Rate and Error Calculation Based on the Slope-Intercept Method with Chromium-51 Ethylenediaminetetraacetic Acid via a New Clinical Software: GFRcalc.基于斜率截距法,使用新型临床软件GFRcalc通过铬-51乙二胺四乙酸进行肾小球滤过率及误差计算
Med Princ Pract. 2016;25(4):368-73. doi: 10.1159/000445028. Epub 2016 Feb 29.