Suppr超能文献

基于斜率截距法,使用新型临床软件GFRcalc通过铬-51乙二胺四乙酸进行肾小球滤过率及误差计算

Glomerular Filtration Rate and Error Calculation Based on the Slope-Intercept Method with Chromium-51 Ethylenediaminetetraacetic Acid via a New Clinical Software: GFRcalc.

作者信息

Geist Barbara Katharina, Diemling Markus, Staudenherz Anton

机构信息

Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Vienna, Austria.

出版信息

Med Princ Pract. 2016;25(4):368-73. doi: 10.1159/000445028. Epub 2016 Feb 29.

Abstract

OBJECTIVE

To evaluate a home-built Java-based program (GFRcalc) to simplify the calculation of glomerular filtration rate (GFR) after administration of chromium-51 ethylenediaminetetraacetic acid (51Cr-EDTA) for routine clinical use.

MATERIALS AND METHODS

In the program GFRcalc, the GFR was calculated based on the biological half-life of the 51Cr-EDTA concentration using the slope-intercept method of between two and five blood samples. Additional features included the ability to export patient data and generate clinical reports as well as to calculate the error of the fit of the GFR measurement in cases with three or more blood samples collected. The GFR was calculated from one, two and three blood samples of 133 patients with body surface-corrected GFR of 21-213 ml/min/1.73 m2. The Pearson correlation coefficient and the error of the fit for the GFR measurement were calculated for the three-sample method.

RESULTS

The correlation coefficient for the three-sample method and the fit error correlated well for small fit errors; in case of fit errors >10%, the correlation coefficient partially differed in results compared to the other methods. The three-sample GFR values differed by approximately 17% from the single-sample GFRs. The fit errors of the three-sample GFRs correlated (r = 0.57) with their difference from the two-sample GFRs.

CONCLUSION

In this study, the fit error that GFRcalc provided for the three-sample GFR offered a simple and reliable method to check the results obtained. This could also allow physicians to assess the reliability of the results and base their decisions on the quality of the measurement.

摘要

目的

评估一个基于Java的自制程序(GFRcalc),以简化静脉注射铬-51乙二胺四乙酸(51Cr-EDTA)后肾小球滤过率(GFR)的计算,供常规临床使用。

材料与方法

在GFRcalc程序中,采用两点至五点血样的斜率截距法,根据51Cr-EDTA浓度的生物半衰期计算GFR。其他功能包括导出患者数据、生成临床报告,以及在采集三个或更多血样的情况下计算GFR测量的拟合误差。从133例患者的一份、两份和三份血样中计算GFR,其体表面积校正后的GFR为21 - 213 ml/min/1.73 m²。对三点法计算GFR的Pearson相关系数和拟合误差进行计算。

结果

对于较小的拟合误差,三点法的相关系数与拟合误差相关性良好;在拟合误差>10%的情况下,与其他方法相比,相关系数结果部分不同。三点法GFR值与单点法GFR值相差约17%。三点法GFR的拟合误差与其与两点法GFR的差值相关(r = 0.57)。

结论

在本研究中,GFRcalc为三点法GFR提供的拟合误差为检查所得结果提供了一种简单可靠的方法。这也可以让医生评估结果的可靠性,并根据测量质量做出决策。