Abstract

PURPOSE

To evaluate the effect of chemical disinfection on the color stability of room temperature vulcanizing (RTV) maxillofacial silicone elastomer with and without pigment addition.

MATERIALS AND METHODS

Sixty specimens were obtained from a RTV maxillofacial silicone. The specimens were randomly divided into 6 groups according to pigments and disinfectant to be used (n = 10). NP-DW-nonpigmented silicone specimens to be immersed in distilled water (control). NP-S- nonpigmented silicone specimens to be rubbed with an anti-bacterial soap. NP-CHX-nonpigmented silicone specimens to be immersed in chlorhexidine gluconate solution (2%). P-DW-pigmented silicone specimens to be immersed in distilled water (control). P-S-pigmented silicone specimens to be rubbed with antibacterial soap. P-CHX-pigmented silicone specimens to be immersed in chlorhexidine gluconate solution (2%). Disinfection was conducted 6 times a day for 60 days simulating 1 year of usage. Color was evaluated after 60 days (disinfection period) using a reflectance spectrophotometer. Color alterations were calculated by the CIE L a b system. Data were analyzed by t-test, one-way ANOVA, and Tukey test (α = 0.05).

RESULTS

NP-S and P-S exhibited the highest color alterations, whereas NP-DW and P-DW the lowest color alterations.

CONCLUSION

Disinfection procedures affect the color stability of maxillofacial silicone. Chlorhexidine gluconate solution (2%) can be effectively used as a chemical disinfectant for maxillofacial prostheses. Antibacterial soap produced clinically unacceptable color changes in the silicone, hence is not advisable as a disinfectant.

摘要

目的

评估化学消毒对添加和不添加颜料的室温硫化(RTV)颌面硅橡胶颜色稳定性的影响。

材料与方法

从 RTV 颌面硅橡胶中获得 60 个样本。根据要使用的颜料和消毒剂,将样本随机分为 6 组(n = 10)。NP-DW-无颜料硅橡胶样本浸入蒸馏水中(对照)。NP-S-无颜料硅橡胶样本用抗菌肥皂摩擦。NP-CHX-无颜料硅橡胶样本浸入葡萄糖酸氯己定溶液(2%)中。P-DW-含颜料硅橡胶样本浸入蒸馏水中(对照)。P-S-含颜料硅橡胶样本用抗菌肥皂摩擦。P-CHX-含颜料硅橡胶样本浸入葡萄糖酸氯己定溶液(2%)中。每天进行 6 次消毒,模拟 1 年的使用。经过 60 天(消毒期)后,使用反射分光光度计评估颜色。颜色变化通过 CIE L a b 系统计算。数据通过 t 检验、单因素方差分析和 Tukey 检验进行分析(α = 0.05)。

结果

NP-S 和 P-S 表现出最高的颜色变化,而 NP-DW 和 P-DW 表现出最低的颜色变化。

结论

消毒程序会影响颌面硅橡胶的颜色稳定性。葡萄糖酸氯己定溶液(2%)可有效用作颌面修复体的化学消毒剂。抗菌肥皂会在硅橡胶上产生临床不可接受的颜色变化,因此不建议作为消毒剂使用。