In this simple, sensitive radioimmunoassay (RIA) of atrial natriuretic polypeptide (hANP) in human plasma, nonspecific interference is minimized by deproteinizing the plasma by heat treatment at 85 degrees C for 10 min. We directly measure alpha-hANP in the supernates by RIA, with use of antiserum that recognizes the N-terminal region of alpha-hANP. The minimal detectable value was 0.4 pg per tube. The intra-assay CV was 6.6% (n = 8). The mean concentration of hANP in plasma of 54 healthy volunteers was 41 (SD 29) ng/L. Concentrations of hANP in plasma increased after saline infusion and high salt intake for one week in patients with essential hypertension. High concentrations were also measured in patients with renal failure and congestive heart failure. This method, which requires no extraction or purification with column chromatography, is especially useful for simultaneous measurement of several samples.
在这种用于检测人血浆中的心钠素(hANP)的简单、灵敏的放射免疫分析(RIA)方法中,通过在85℃下对血浆进行10分钟的热处理使其脱蛋白,从而将非特异性干扰降至最低。我们使用识别α-hANP N端区域的抗血清,通过RIA直接测定上清液中的α-hANP。最低检测值为每管0.4皮克。批内变异系数为6.6%(n = 8)。54名健康志愿者血浆中hANP的平均浓度为41(标准差29)纳克/升。原发性高血压患者在输注生理盐水和高盐饮食一周后,血浆中hANP的浓度升高。在肾衰竭和充血性心力衰竭患者中也检测到高浓度的hANP。这种方法无需柱色谱提取或纯化,特别适用于同时检测多个样本。