Capping and lamination are common industrial problems during the manufacturing of pharmaceutical tablets. Even if they are commonly treated together, these phenomena correspond to different failure patterns of the tablet and, as a consequence, to different mechanisms of cracking. In this work, a specific case of lamination of biconvex tablets was studied. It corresponds to a breakage into two parts of the tablets along a failure plan normal to the compression direction and located approximately at the center of the tablet band. Simulation with finite element method made it possible to propose that this kind of failure is promoted by tensile stresses localized at the center of the tablet that are induced by the residual die wall pressure and the tablet shape. Moreover, these stresses are favored by a small band thickness. Experimental results confirmed these hypotheses and also showed that this kind of lamination was favored by a high compaction pressure. As the crack is formed at the center of the tablet, it may not propagate until the tablet band. Failure may thus remain undetected by external visual examination. X-ray tomography made it possible to observe central cracks inside the tablet without tablet breakage. The possibility to have such cracks inside the tablet must be considered during tablet development as, even if not detected just after compression, they could lead to tablet failure during post compaction events.
顶裂和分层是制药片剂生产过程中的常见工业问题。即使它们通常一起处理,但这些现象对应于片剂的不同失效模式,因此也对应于不同的开裂机制。在这项工作中,研究了一种特殊的双凸片剂分层情况。它对应于片剂沿着垂直于压缩方向的失效面断裂成两部分,并且该失效面大致位于片剂带的中心。有限元法的模拟表明,这种失效是由残余模壁压力和片剂形状引起的集中在片剂中心的拉伸应力引起的。此外,这些应力受到较窄的带厚度的促进。实验结果证实了这些假设,还表明这种分层现象受到较高的压缩压力的促进。由于裂缝是在片剂中心形成的,因此它可能不会在片剂带中传播。因此,外部目视检查可能无法检测到失效。X 射线断层扫描使得可以在不破坏片剂的情况下观察片剂内部的中心裂缝。在片剂开发过程中必须考虑片剂内部存在这种裂缝的可能性,因为即使在压缩后没有立即检测到,它们也可能在压缩后导致片剂失效。