Abstract

PURPOSE

This in vitro study assessed the accuracy of multiple implant-level impression techniques (open tray and closed tray) for the fabrication of 3-unit implant prostheses with strain gauge (SG) analysis.

MATERIALS AND METHODS

A polyurethane master model was designed to simulate a clinical situation. Two rigid custom trays were fabricated for the model. The impression material used was polysulfide. Transfer implant impressions were made using 2 techniques; ten tapered copings not splinted (custom closed tray) and ten square copings splinted with acrylic-resin (custom open tray). The improved stone models were allowed to set for 1 hour before being separated from the impression. The superstructures were sprued, invested, and cast with a cobalt-chromium alloy. Four SGs were bonded on the surface of each polyurethane block.

RESULTS

A statistically significant difference was found between the 2 impression techniques tested (P = 0.000). This study found a significant average difference of 144.68 ± 5.53 με for open custom tray and 253.3 ± 16.7 με for closed custom tray.

CONCLUSION

The custom open tray technique was the most accurate impression for multiple implants compared with closed custom tray.

摘要

目的

本体外研究通过应变片(SG)分析评估了多种种植体水平印模技术(开放托盘和封闭托盘)用于制作3单位种植修复体的准确性。

材料与方法

设计一个聚氨酯主模型以模拟临床情况。为该模型制作了两个刚性定制托盘。使用的印模材料是聚硫化物。采用两种技术制取转移种植体印模;十个未用夹板固定的锥形桩帽(定制封闭托盘)和十个用丙烯酸树脂夹板固定的方形桩帽(定制开放托盘)。改良的石膏模型在与印模分离前放置1小时。对上部结构进行浇铸道设置、包埋,并使用钴铬合金铸造。在每个聚氨酯块的表面粘贴四个应变片。

结果

在所测试的两种印模技术之间发现了统计学上的显著差异(P = 0.000)。本研究发现,定制开放托盘的平均差异显著,为144.68±5.53με,定制封闭托盘为253.3±16.7με。

结论

与定制封闭托盘相比,定制开放托盘技术对于多个种植体来说是最准确的印模。