Suppr超能文献

根管器械预备时带蓝色锥度的 Reciproc 、 FlexWave EDM 、 XP-endo Shaper 镍钛锉根尖挤出物的比较

Apically Extruded Debris during Root Canal Instrumentation with Reciproc Blue, HyFlex EDM, and XP-endo Shaper Nickel-titanium Files.

机构信息

Private Practice, Dental Clinic, Çanakkale, Turkey.

Department of Endodontics, Faculty of Dentistry, Ondokuz Mayıs University, Samsun, Turkey.

出版信息

J Endod. 2018 May;44(5):856-859. doi: 10.1016/j.joen.2018.01.018. Epub 2018 Mar 15.

Abstract

INTRODUCTION

The purpose of this study was to investigate the amount of apically extruded debris by Reciproc Blue (REC Blue; VDW, Munich, Germany), HyFlex EDM (HEDM; Coltene/Whaledent, Altstätten, Switzerland), and XP-endo Shaper (XPS; FKG Dentaire SA, La Chaux-de-Fonds, Switzerland) files during root canal preparation at body temperature.

METHODS

Sixty extracted single-rooted mandibular premolar human teeth were randomly assigned to 3 groups (n = 20). The canals were instrumented using 1 of the following instruments: REC Blue, HEDM, or XPS. Apically extruded debris during instrumentation was collected into preweighed Eppendorf tubes. All the procedures were performed at 35°C. The amount of extruded debris was calculated by subtracting the weight value of the tooth-free apparatus from the postpreparation weight value. The data were analyzed using the Kruskal-Wallis test at a 5% significance level.

RESULTS

All the instruments tested caused extrusion of some debris from the apical foramen. XPS extruded significantly less debris from the apex than REC Blue (P < .05). The difference among the HEDM group and the other groups was not significant (P > .05).

CONCLUSIONS

Within the limitations of this in vitro study, the amount of apically extruded debris registered for the different files tested was REC Blue > HEDM > XPS, with a statistical difference only between XPS and REC Blue.

摘要

简介

本研究的目的是在体温下研究 Reciproc Blue(REC Blue;VDW,慕尼黑,德国)、HyFlex EDM(HEDM;Coltene/Whaledent,阿尔特施塔特,瑞士)和 XP-endo Shaper(XPS;FKG Dentaire SA,拉绍德封,瑞士)锉在根管预备过程中从根尖挤出的碎屑量。

方法

将 60 颗提取的下颌前磨牙随机分为 3 组(n = 20)。使用以下器械之一对根管进行器械处理:REC Blue、HEDM 或 XPS。在器械处理过程中从根尖挤出的碎屑被收集到预先称重的 Eppendorf 管中。所有程序均在 35°C 下进行。通过从预备后的牙齿重量值中减去无牙器械的重量值来计算挤出的碎屑量。使用 Kruskal-Wallis 检验在 5%的显著性水平下对数据进行分析。

结果

所有测试的器械都从根尖孔挤出了一些碎屑。XPS 从根尖挤出的碎屑明显少于 REC Blue(P <.05)。HEDM 组与其他组之间的差异无统计学意义(P >.05)。

结论

在本体外研究的限制范围内,不同测试文件从根尖挤出的碎屑量为 REC Blue > HEDM > XPS,仅在 XPS 和 REC Blue 之间存在统计学差异。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验