瑞典交互式阈值算法和标准全阈值视野检查法在原发性开角型青光眼中的敏感度和特异度

Sensitivity and Specificity of Swedish Interactive Threshold Algorithm and Standard Full Threshold Perimetry in Primary Open-angle Glaucoma.

作者信息

Bamdad Shahram, Beigi Vahid, Sedaghat Mohammad Reza

机构信息

Associate Professor, Department of Ophthalmology, Poostchi Ophthalmology Research Center, School of Medicine, Shiraz University of Medical Sciences, Shiraz, Iran.

Resident of Ophthalmology, Poostchi Ophthalmology Research Center, School of Medicine, Shiraz University of Medical Sciences, Shiraz, Iran.

出版信息

Med Hypothesis Discov Innov Ophthalmol. 2017 Winter;6(4):125-129.

Abstract

Perimetry is one of the mainstays in glaucoma diagnosis and treatment. Various strategies offer different accuracies in glaucoma testing. Our aim was to determine and compare the diagnostic sensitivity and specificity of Swedish Interactive Threshold Algorithm (SITA) Fast and Standard Full Threshold (SFT) strategies of the Humphrey Field Analyzer (HFA) in identifying patients with visual field defect in glaucoma disease. This prospective observational case series study was conducted in a university-based eye hospital. A total of 37 eyes of 20 patients with glaucoma were evaluated using the central 30-2 program and both the SITA Fast and SFT strategies. Both strategies were performed for each strategy in each session and for four times in a 2-week period. Data were analyzed using the Student's t-test, analysis of variance, and chi-square test. The SITA Fast and SFT strategies had similar sensitivity of 93.3%. The specificity of SITA Fast and SFT strategies was 57.4% and 71.4% respectively. The mean duration of SFT tests was 14.6 minutes, and that of SITA Fast tests was 5.45 minutes (a statistically significant 62.5% reduction). In gray scale plots, visual field defect was less deep in SITA Fast than in SFT; however, more points had significant defect (p < 0.5% and p < 1%) in pattern deviation plots in SITA Fast than in SFT; these differences were not clinically significant. In conclusion, the SITA Fast strategy showed higher sensitivity for detection of glaucoma compared to the SFT strategy, yet with reduced specificity; however, the shorter test duration makes it a more acceptable choice in many clinical situations, especially for children, elderly, and those with musculoskeletal diseases.

摘要

视野检查是青光眼诊断和治疗的主要手段之一。在青光眼检测中,各种策略具有不同的准确性。我们的目的是确定并比较Humphrey视野分析仪(HFA)的瑞典交互式阈值算法(SITA)快速策略和标准全阈值(SFT)策略在识别青光眼患者视野缺损方面的诊断敏感性和特异性。这项前瞻性观察性病例系列研究在一家大学眼科医院进行。使用中央30-2程序以及SITA快速策略和SFT策略对20例青光眼患者的37只眼睛进行了评估。在每个检查阶段,对每种策略都进行了两次检查,并在两周内进行了四次。使用学生t检验、方差分析和卡方检验对数据进行分析。SITA快速策略和SFT策略的敏感性相似,均为93.3%。SITA快速策略和SFT策略的特异性分别为57.4%和71.4%。SFT测试的平均时长为14.6分钟,而SITA快速测试的平均时长为5.45分钟(在统计学上显著减少了62.5%)。在灰度图中,SITA快速策略的视野缺损比SFT策略的浅;然而,在模式偏差图中,SITA快速策略中具有显著缺损的点数(p<0.5%和p<1%)比SFT策略中的多;这些差异在临床上并不显著。总之,与SFT策略相比,SITA快速策略在检测青光眼方面显示出更高的敏感性,但特异性降低;然而,较短的测试时长使其在许多临床情况下成为更可接受的选择,特别是对于儿童、老年人以及患有肌肉骨骼疾病的患者。

相似文献

6
The SITA perimetric threshold algorithms in glaucoma.
Invest Ophthalmol Vis Sci. 1999 Aug;40(9):1998-2009.

引用本文的文献

1
Concordance of 24-h intraocular pressure curve in patients with untreated unilateral primary open-angle glaucoma.
Exp Ther Med. 2018 Aug;16(2):1461-1469. doi: 10.3892/etm.2018.6315. Epub 2018 Jun 15.

本文引用的文献

4
Fatigue effects in automated perimetry.
Appl Opt. 1988 Mar 15;27(6):1030-7. doi: 10.1364/AO.27.001030.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验