Suppr超能文献

载银活性炭(SIAC)预处理对银浸出和溴化物去除性能的影响。

Effect of preconditioning on silver leaching and bromide removal properties of silver-impregnated activated carbon (SIAC).

机构信息

Department of Civil Engineering, Curtin University, GPO Box U1987, Perth, WA 6845, Australia.

Curtin Water Quality Research Centre, Department of Chemistry, Curtin University, GPO Box U1987, Perth, WA 6845, Australia.

出版信息

Water Res. 2018 Jul 1;138:152-159. doi: 10.1016/j.watres.2018.03.026. Epub 2018 Mar 12.

Abstract

Silver impregnated activated carbon (SIAC) has been found to be effective in mitigating the formation of brominated-disinfection by products during drinking water treatment. However, there are still uncertainties regarding its silver leaching properties, and strategies for the prevention of silver leaching have remained elusive. This study focused on the evaluation of one type of commercially available SIAC for its ability to remove bromide while minimising silver leaching from the material. Both synthetic and real water matrices were tested. Depending on solution pH, it was found that changing the surface charge properties of SIAC, as measured by the point of zero charge pH, can result in additional bromide removal while minimising the extent of silver leaching. To better understand the mechanism of silver leaching from the SIAC, eight preconditioning environments, i.e. variable pH and ionic strength were tested for a fixed amount of SIAC and two preconditioning environments were selected for a more detailed investigation. Experiments carried out in synthetic water showed that preconditioning at pH 10.4 did not deteriorate the capacity of SIAC to remove bromide, but significantly decreased the release of silver in the form of ionic silver (Ag), silver bromide (AgBr) and silver chloride (AgCl) from 40% for the pristine to 3% for the treated SIAC. This was confirmed using a groundwater sample. These results suggest that preconditioned SIAC has the potential to be an effective method for bromide removal with minimised silver leaching in a long-term field application for drinking water production.

摘要

载银活性炭(SIAC)已被证明在减轻饮用水处理过程中溴代消毒副产物的形成方面非常有效。然而,其银浸出特性仍存在不确定性,防止银浸出的策略仍然难以捉摸。本研究专注于评估一种市售的 SIAC 去除溴化物的能力,同时最大限度地减少材料中的银浸出。对合成水和实际水基质进行了测试。结果发现,根据溶液 pH 值,通过零电荷 pH 值测量的 SIAC 表面电荷特性的变化可以在最大限度地减少银浸出的同时,进一步去除溴化物。为了更好地理解 SIAC 中银浸出的机制,测试了八种预处理环境,即可变 pH 值和离子强度,对于固定量的 SIAC 进行了测试,并选择了两种预处理环境进行更详细的研究。在合成水中进行的实验表明,在 pH 值为 10.4 下预处理不会降低 SIAC 去除溴化物的能力,但会显著减少以离子银 (Ag)、溴化银 (AgBr) 和氯化银 (AgCl) 的形式从原始 SIAC 的 40%到处理后的 SIAC 的 3%释放银。这在地下水样本中得到了证实。这些结果表明,预处理后的 SIAC 有可能成为一种有效的方法,用于在饮用水生产的长期现场应用中去除溴化物并最大限度地减少银浸出。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验