Abstract

OBJECTIVE

The objective of this study was to assess the accuracy of the quantitative measurements obtained using dual-energy computed tomography with metal artifact reduction software (MARS).

METHODS

Dual-energy computed tomography scans (fast kV-switching) are performed on a phantom, by varying the number of metal rods (Ti and Pb) and reference iodine materials. Objective and subjective image analyses are performed on retroreconstructed virtual monochromatic images (VMIs) (VMI at 70 keV).

RESULTS

The maximum artifact indices for VMI-Ti and VMI-Pb (5 metal rods) with MARS (without MARS) were 17.4 (166.7) and 34.6 (810.6), respectively; MARS significantly improved the mean subjective 5-point score (P < 0.05). The maximum differences between the measured Hounsfield unit and theoretical values for 5 mg/mL iodine and 2-mm core rods were -42.2% and -68.5%, for VMI-Ti and VMI-Pb (5 metal rods), respectively, and the corresponding differences in the iodine concentration were -64.7% and -73.0%, respectively.

CONCLUSIONS

Metal artifact reduction software improved the objective and subjective image quality; however, the quantitative values were underestimated.

摘要

目的

本研究的目的是评估使用具有金属伪影减少软件(MARS)的双能计算机断层扫描获得的定量测量的准确性。

方法

通过改变金属棒(钛和铅)的数量以及参考碘物质,在体模上进行双能计算机断层扫描(快速千伏切换)。对重建后的虚拟单色图像(VMI)(70keV的VMI)进行客观和主观图像分析。

结果

使用MARS(不使用MARS)时,VMI-钛和VMI-铅(5根金属棒)的最大伪影指数分别为17.4(166.7)和34.6(810.6);MARS显著提高了平均主观5分评分(P<0.05)。对于5mg/mL碘和2mm芯棒,VMI-钛和VMI-铅(5根金属棒)的测量亨氏单位与理论值之间的最大差异分别为-42.2%和-68.5%,碘浓度的相应差异分别为-64.7%和-73.0%。

结论

金属伪影减少软件改善了客观和主观图像质量;然而,定量值被低估了。