Suppr超能文献

采用中央对中央技术缝合纽扣置入治疗下胫腓联合固定时的中间结构损伤。

Medial Structure Injury During Suture Button Insertion Using the Center-Center Technique for Syndesmotic Stabilization.

机构信息

1 Foot and Ankle Division, Department of Orthopaedics and Rehabilitation, University of Florida, Gainesville, FL, USA.

2 Orthopedic Foot and Ankle Center, Westerville, OH, USA.

出版信息

Foot Ankle Int. 2018 Aug;39(8):984-989. doi: 10.1177/1071100718770200. Epub 2018 Apr 11.

Abstract

BACKGROUND

The center-center technique for syndesmosis fixation has been described as an improved and reliable technique for proper reduction of the syndesmosis during ankle fracture repair. Concurrently, the use of flexible fixation with a suture button is becoming an established means of syndesmosis stabilization. The purpose of this cadaveric study was to assess for medial structure injury during the placement of a suture button using the center-center technique for ankle syndesmosis repair at 3 insertion intervals.

METHODS

Simulated open syndesmosis repair was performed on 10 cadaveric specimens. Three intervals were measured at 10 mm, 20 mm, and 30 mm proximal to the level of the distal tibial articular surface along the fibula. Proper longitudinal alignment of the center-center technique was completed under fluoroscopic guidance and was marked on the medial aspect of the tibia. The 3 intervals were drilled in the appropriate technique trajectory. The suture button was subsequently passed through each drill-hole interval. A single observer used a digital caliper to measure the distance from each suture button aperture with respect to the tibialis anterior tendon, tibialis posterior tendon, and greater saphenous vein and nerve.

RESULTS

A total of 30 interval measurements (10 cadavers with 3 suture button segments each) were used for data analysis. Direct impingement on the greater saphenous vein was seen in 11 of 30 (36.6%) interval measurements. Six of the 11 (54.5%) observed saphenous structure impingement events occurred at the 10-mm drill hole.

CONCLUSION

The results of the present study suggest that the use of the center-center technique for syndesmosis repair with suture button fixation risks preventable injury to the greater saphenous neurovasculature.

CLINICAL RELEVANCE

To understand the medial ankle anatomy, as it pertains to insertion of flexible syndesmotic fixation in a cadaveric model, to aid in prevention of clinical iatrogenic injury.

摘要

背景

中心-中心技术已被描述为一种改进且可靠的技术,可在修复踝关节骨折时适当复位下胫腓联合。同时,使用缝线纽扣的灵活固定已成为稳定下胫腓联合的一种既定手段。本尸体研究的目的是评估在踝关节下胫腓联合修复中使用中心-中心技术时,在 3 个插入间隔处使用缝线纽扣固定时对内侧结构的损伤。

方法

在 10 个尸体标本上模拟开放性下胫腓联合修复。在距腓骨远端关节面 10mm、20mm 和 30mm 处测量 3 个间隔,在胫骨内侧标记适当的中心-中心技术的纵向对齐。在透视引导下完成中心-中心技术的正确纵向对齐,并在胫骨内侧标记。按照适当的技术轨迹钻 3 个间隔。随后将缝线纽扣穿过每个钻孔间隔。一位观察者使用数字卡尺测量每个缝线纽扣孔相对于胫骨前肌腱、胫骨后肌腱和大隐静脉和神经的距离。

结果

共对 30 个间隔测量值(每个标本 10 个,每个标本 3 个缝线纽扣段)进行数据分析。在 30 个间隔测量值中,有 11 个(36.6%)观察到直接撞击大隐静脉。在观察到的 11 个(54.5%)隐静脉结构撞击事件中,有 6 个发生在 10mm 钻孔处。

结论

本研究结果表明,使用中心-中心技术结合缝线纽扣固定修复下胫腓联合可能会对内侧隐静脉的神经血管造成可预防的损伤。

临床意义

了解与尸体模型中灵活的下胫腓联合固定相关的内踝解剖结构,以帮助预防临床医源性损伤。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验