Qiao Xiao-Feng, Li Xin, Wang Dong, Li Tong-Li
ENT and HN Surgery Department, Shanxi Provincial People's Hospital Affiliated to Shanxi Medical University, Taiyuan, China.
Department of Surgery, Children's Hospital of Shanxi Province, Taiyuan, China.
ORL J Otorhinolaryngol Relat Spec. 2018;80(1):51-57. doi: 10.1159/000487238. Epub 2018 Apr 19.
This study aims to investigate the correlation between thresholds of preoperative multiple auditory steady-state response (ASSR) and electrically evoked auditory brainstem response (EABR) and the behavioral threshold.
A total of 72 patients were elected to receive a multichannel cochlear implant. According to the residual hearing determined in a preoperative test using high-, moderate-, and low-frequency ASSR, these patients were divided into the following 2 groups: residual hearing and hearing loss. The EABR and behavioral thresholds 1 year after implantation were assayed, and differences between these 2 parameters were compared.
Among the high-, moderate-, and low-frequency residual hearing groups, the EABR and behavioral thresholds of patients 1 year after implantation were significantly lower than those in the hearing loss group, and the differences were statistically significant (p < 0.01).
Before the operation, ASSR results can be used to predict the efficacy of cochlear implantation in patients, and they serve as one of the reference conditions for choosing the ear for implantation. However, the threshold of ASSR is not equivalent to the actual auditory threshold of patients after implantation, and the deviation between these 2 thresholds is more significant at low frequencies.
本研究旨在探讨术前多频听觉稳态反应(ASSR)阈值和电诱发听觉脑干反应(EABR)阈值与行为阈值之间的相关性。
共选取72例患者接受多通道人工耳蜗植入。根据术前使用高频、中频和低频ASSR测试确定的残余听力,将这些患者分为以下两组:残余听力组和听力损失组。测定植入后1年的EABR和行为阈值,并比较这两个参数之间的差异。
在高频、中频和低频残余听力组中,植入后1年患者的EABR和行为阈值显著低于听力损失组,差异具有统计学意义(p < 0.01)。
术前,ASSR结果可用于预测患者人工耳蜗植入的疗效,且作为选择植入耳的参考条件之一。然而,ASSR阈值并不等同于患者植入后实际的听觉阈值,且这两个阈值在低频时的偏差更为显著。