Suppr超能文献

通过动态灌注单光子发射计算机断层扫描得出的心肌血流储备反映了冠状动脉粥样硬化的严重程度。

Myocardial flow reserve derived by dynamic perfusion single-photon emission computed tomography reflects the severity of coronary atherosclerosis.

作者信息

Iguchi Nobuo, Utanohara Yuko, Suzuki Yasuhiro, Suzuki Makoto, Hagiya Kenichi, Higuchi Ryosuke, Takamisawa Itaru, Tobaru Tetsuya, Sumiyoshi Tetsuya, Isobe Mitsuaki

机构信息

Department of Cardiology, Sakakibara Heart Institute, 3-16-1 Asahi-Cho, Fuchu, Tokyo, 183-0003, Japan.

Department of Radiology, Sakakibara Heart Institute, Tokyo, Japan.

出版信息

Int J Cardiovasc Imaging. 2018 Sep;34(9):1493-1501. doi: 10.1007/s10554-018-1358-5. Epub 2018 Apr 20.

Abstract

A novel single-photon emission computed tomography (SPECT) camera was developed to evaluate dynamic myocardial perfusion flow. However, it is unclear whether myocardial flow reserve (MFR) derived by dynamic perfusion SPECT using the novel SPECT camera (D-SPECT) reflects the severity of coronary atherosclerosis. In the present study, we therefore examined the relationship between MFR using D-SPECT and severity of coronary lesions. The study population comprised 40 patients who underwent both a myocardial dynamic perfusion SPECT study and invasive coronary angiography. The severity of coronary atherosclerosis was evaluated using the Gensini score. All patients underwent a rest/stress SPECT imaging protocol using Tc-99m-sestamibi, and dynamic acquisition was performed. Stress and rest flow was evaluated, and the global and regional MFR was calculated. Global MFR showed a significant negative correlation with Gensini score (r = - 0.345, p = 0.037). Multiple linear regression analysis showed that only global MFR was independently related to Gensini score (p = 0.018). Regional MFR was significantly lower in regions with  90% ≤ stenotic lesions compared with regions with < 90% stenotic lesions (p = 0.009). Global MFR derived by dynamic perfusion SPECT using D-SPECT reflects the severity of coronary atherosclerosis. Further, regional MFR is modulated by severe coronary artery stenotic lesions.

摘要

为评估动态心肌灌注血流,研发了一种新型单光子发射计算机断层扫描(SPECT)相机。然而,尚不清楚使用这种新型SPECT相机(D-SPECT)通过动态灌注SPECT得出的心肌血流储备(MFR)是否反映冠状动脉粥样硬化的严重程度。因此,在本研究中,我们检测了使用D-SPECT的MFR与冠状动脉病变严重程度之间的关系。研究人群包括40例同时接受心肌动态灌注SPECT研究和有创冠状动脉造影的患者。使用Gensini评分评估冠状动脉粥样硬化的严重程度。所有患者均采用Tc-99m-甲氧基异丁基异腈进行静息/负荷SPECT成像方案,并进行动态采集。评估负荷和静息血流,并计算整体和局部MFR。整体MFR与Gensini评分呈显著负相关(r = -0.345,p = 0.037)。多元线性回归分析显示,只有整体MFR与Gensini评分独立相关(p = 0.018)。与狭窄病变<90%的区域相比,狭窄病变≥90%的区域局部MFR显著降低(p = 0.009)。使用D-SPECT通过动态灌注SPECT得出的整体MFR反映冠状动脉粥样硬化的严重程度。此外,局部MFR受严重冠状动脉狭窄病变的调节。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验